background image

 

 

 6  

 

R

e

v

is

n

: 0

5

   

  R

e

f.:

 M

A

N

U

_

V

B

Z

   

 1

6

/0

2

/2

0

1

7

 

 

To maintain NSF Sanitation listing cases must have sealed to the floor. 

Use NSF sealant such as silicone or equivalent cove mouldings or tiles are acceptable. 

Do not block any louvered holes. 

 

Before starting-up and placing any food inside the cabinet, firstly remove 

the  protective  film  and  then  clean  the  complete  unit  thoroughly.  If  any 

adhesive  remains,  eliminate  it  with  alcohol.  Washing  with  a  mild  soap 

and  warm  water  solution  is  recommended  for  cleaning  all  the  stainless 

steel surfaces of your cabinet. This should be followed by cleaning with a 

baking  soda  solution.  Rinse  thoroughly  with  clear  water  and  dry  with  a 

clean, soft cloth. 

 

NOTE:  Never  use  abrasive  or  harsh  cleaners,  concentrated  detergents,  solvents  or  chemicals 

when cleaning the unit.  

 

The supply voltage should be checked before connection to assure that proper voltage for the 

cabinet  wiring  is  available.    To  determine  correct  unit  voltage,  please  refer  to  the  serial  data  plate 

located  on  an  inner  wall  of  the  unit.  Verify  that  this  information  exactly  matches  the  electrical 

characteristics at the installation location.  

 

NOTE:  Infrico  requires  that  a  sole  use  circuit  be  dedicated  for  the  unit.  Failure  to  do  so  voids 

warranty. 

 

NOTE: The unit is designed to operate with a voltage fluctuation of 5% of the voltage indicated 

on  the  cabinet  serial  data  plate.  Burnout  of  the  compressor  due  to  exceeding  the  high  or  low 

voltage limits will automatically void the factory warranty.  

 

Units are provided with a U.L. approved power cord and plug which is factory installed. Infrico 

uses for VBZ cases NEMA 5-15P plugs. If you do not have the right outlet have a certified electrician 

install the correct power source: 

                                               
        

   

 

5.5

 

Sealing Case to Floor 

5.6

 

Initial cleaning procedure 

6

 

ELECTRICAL INSTRUCTIONS 

115 / 60 / 1 NEMA 5-15P

 

Summary of Contents for VBZ Ibiza

Page 1: ...VBZ Ibiza Cases GELATO DISPLAY CASES Service Installation Manual...

Page 2: ...CEDURE 7 8 OPERATION 7 8 1 Temperature control adjustment 7 8 2 Defrost control 8 8 3 Loading product 10 9 MAINTENANCE CARE AND CLEANING 10 9 1 Cleaning procedure 10 9 2 Parts and Service Error Marcad...

Page 3: ...cluding the following This refrigerator must be properly installed and located in accordance with this manual before it is used Do not allow children to climb stand or hang on the shelves in the refri...

Page 4: ...nt This unit is intended for indoor use only Be sure the location chosen for your unit must be able to provide good air circulation for most efficient refrigeration Avoid locations near heat sources s...

Page 5: ...front side or back However you must be certain to allow the unit to remain in an upright position afterwards for at least 24 hours before plugging it in so that the compressor oil and refrigerant may...

Page 6: ...e should be checked before connection to assure that proper voltage for the cabinet wiring is available To determine correct unit voltage please refer to the serial data plate located on an inner wall...

Page 7: ...ercial standards If any unusual noises are heard turn the unit off immediately and check for any obstructions of the fans All cabinets must be given enough time to reach normal operating temperature b...

Page 8: ...Menu mode it is used to look through the parameter codes or decrease the value of the variable in use This turns the light on and off Note while in the OFF status the light button is active VBZ ice c...

Page 9: ...wo defrost cycles To adjust this parameter you may follow the next instruction 1 Enter the Programming mode by pressing the SET DOWN keys for 3s the C or F LED starts blinking 2 Select the required pa...

Page 10: ...binet Do not leave food inside the unit when it is going to remain shut down either from a power outage or fault in the equipment If the cabinet is going to remain shut down for prolonged periods try...

Page 11: ...st be able to freely circulate through the condenser so the surface of the condenser must be kept free of dirt and grease for proper system operation Dirty condensers result in compressor failure and...

Page 12: ...to back up and overflow the drain pans Many operating problems are derived from causes that can be easily eliminated without the need to contact the Technical Department The following page shows a ta...

Page 13: ...ective 3 Overload protector defective 4 High head pressure 5 Fan motor pump etc wire to wrong of overload protector Compressor starts but immediately cuts out on overload 1 Starting relay contacts poi...

Page 14: ...Fixture doors left open too long 8 Insufficient defective or water logged insulation 9 Evaporated oil logged Noisy unit 1 Compressor oil charge low 2 Fan cable on condenser or evaporator bent causing...

Page 15: ...r authorization by Infrico In addition to the warranty set above Infrico warrants the hermetically and semi hermetically sealed compressor part only for an additional four 4 years based on the install...

Page 16: ...pparatus is not functioning correctly users must make the checks indicated in the manual and if the problem persists contact their distributor This certificate must be presented if it is necessary for...

Page 17: ...improper or non compliant installation of the apparatus connection voltage power supply fluctuations electrical connection not conforming to instructions etc or from manipulation of the nameplate or o...

Page 18: ...___________ Compressor No __________________________ Vendor Signature Purchaser Signature R E T U R N T O T H E M A N U F A C T U R E R User ___________________________________________________________...

Page 19: ...Infrico SL CR CO 762 Los Piedros Las Navas s n 14900 Lucena C rdoba Espa a 00 34 957 59 51 16 office 00 34 957 59 51 06 fax asistenciatecnica infrico com info infrico com www infrico com...