3. TECHNICAL DATA
•
Range of
sauna mode
settings:
Sauna mode:
Cabin temp.: 30 - 110 °C, Operating period: 30 min - 20 hrs
Evaporator:
Cabin temp.: 30 - 65 °C, Op. period: 30 min - 20 hrs, 10 – 99% rel. humidity
Surface heat:
Cabin temp.: 20 - 50 °C, Op. period: 30 min - 20 hrs, surface temp.: 30 – 80 °C
Radiator:
Cabin temp.: 20 - 50 °C, Op. period: 30 min - 20 hrs, power: 40 - 100%
•
Nominal voltage:
400 V, 3N AC, 50 Hz
•
Power:
max. 11 kW with sauna mode, extensible by connection of a power circuit
breaker
max. 7.2 kW and 3.5 kW evaporator with evaporator mode
max. 1.3 kW for infrared radiator (1 or 2 controls for max. 2 x 500 W)
max. 3.5 kW for infrared surface heating
max. 3.5 kW for combined surface heating and evaporator mode
•
Light:
230 V AC, 100 W
•
Ventilator function:
230 V AC, 100 W, overrun time programmable up to 60 min
•
Ambient temperature:
0 - 40 °C
•
Storage temperature:
-20 - 70 °C
•
Heating time limit:
Adjustable up to 6 (20) hrs
•
Error indicator:
Automatic error detection shown in text on the LCD-display in the event of
disconnection or damaged sensor
• Safety cut-off:
Over-temperature fuse in the sensor unit
•
Lack of water:
External control, buzzer in the evaporator heater, indication in the display
•
Connection for lack of water, cover protection system and/or door contact switch
•
Connection for a power extension by means of a safety contactor or relay
•
Extra 230 V output for coloured light or music
• Device main switch (power on/off), no standby power consumption
•
Programming remains stored even after a power failure
•
Child lock can be activated
•
Preselection time can be activated, if combined with door contact switch or rocker
•
Operating and heating time statistics of the total working time can be retrieved
•
Menu navigation in German, English (optionally: Italian, French, Dutch)
•
Option: Connection for remote start possible, if combined with door contact switch or rocker
(start impulse or continuous contact)
2. PARTS LIST
•
Power unit with aluminium housing (HxWxD: 60 x 240 x 215 mm)
•
Operating unit with four-line LCD display (HxWxD: 145 x 135 x 24 mm) and backlighting,
3 m connecting cable to the power unit
•
Control for infrared radiator with 4.0 m cable
•
Sensor unit (safety and cabin temperature sensor) with 3.5 m silicone cable
•
Surface sensor with 4 m cable
•
Instructions for assembly and use
•
Drilling template