Thank you very much for purchasing a INFRATECH Quartz Tube Electric Heater.

We have designed this heater to provide you and your family with many years of great outdoor experiences. Please fill 

in the Model and Serial number as well as date of purchase in the areas indicated above. Please save this information 

for future reference. To get the full and safe enjoyment of your electric heater please read this Owner’s Manual 

carefully and review the proper operating and safety instructions with any family members that may be using the 

heater.

Manufacturer Warranty:

INFRATECH warrants that this electric heater is designed and manufactured to be free from defects in materials and 

workmanship for a period of  two years from original date of purchase. 

Extent of Warranty:

This warranty extends to the selling dealers to the original purchaser at the original site of installation: This warranty 

becomes valid at the time of purchase and ends either by specified time frame listed above, owner transfer or 

relocation. In order to activate the warranty we require that you send in the attached warranty registration form. This 

registration is for our internal use only and will only be used in the event we need to send you important safety related 

product information. The information will not be sold or used for any marketing related purposes.

Warranty Limitations and Exclusions:

This warranty does not apply to damages resulting from negligence, alteration, misuse, abuse, accident, natural 

disaster, improper installation or improper operation, unauthorized adjustments or calibrations, dings, dents, 

scratches, nor damages due to harsh chemicals (i.e. cleaning products improperly applied). Warrantor is not 

responsible for consequential or incidental damages. Under no circumstances shall INFRATECH or any of its 

representatives be held liable for injury to any person or damage to any property, however arising.

Important: Please retain original proof of purchase to establish warranty period.

Any implied warranties of merchantability and fitness applicable to the equipment are limited in duration to the period 

of coverage of this express written warranty. This warranty grants specific legal rights to the purchaser. Other rights, 

which may vary from state to state, may also apply. Title to the merchandise passes to the consignee upon acceptance 

by the carrier. After acceptance by the carrier, the merchandise travels at the risk of the purchaser. In the event of 

freight damage, do not refuse shipment. Advise both the freight agent and the shipper of the damage. Note the details 

of that damage on the freight bill before any freight charges are paid and file a claim for damages with the freight 

agent. ©2008 INFRATECH 

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

CUT HERE 

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - --

RATECH WARRANTY REGISTRATION                                                                                                 

Customer Name:

Address:

City:

State:

Zip:

Phone:

E-mail:

Model #:

Serial #:

Dealer's Name:

Date Purchased:

Dealer's Address:

This Warranty Registration Card must be returned within thirty days of purchase to properly activate your warranty. 

This information is for our internal use only.

15700 South Figueroa Street Gardena, CA 90248

TEL 

800-421-9455 or 310-354-1250 

FAX 

310-523-3674 

INFRATECH-USA.COM

LIMITED PRODUCT WARRANTY

INFRATECH WARRANTY REGISTRATION

Summary of Contents for W series

Page 1: ...TABLE OF CONTENTS Warnings 2 Installation Instructions 3 Wiring Instructions 3 Mounting Instructions 4 Replacement Element Installation 5 Replacement Parts 5 Heater Coverage Areas 6 General Notes 6 Maintenance Instructions 6 Trouble Shooting 7 Location Suggestions 7 Warranty 8 ...

Page 2: ...nward angle of 30 to 60 degrees For Ceiling Mounting do not install heater closer than 18 45 7cm from adjacent walls and 6 15 2cm from ceiling and do not install less than 6 1 8 m if the heater is labeled as UL Listed and 8 2 4m if the heater is labeled as UL CUL Listed from floor while heater is at a maximum 30 degrees Adjacent Heaters to be installed no less than 3 0 9 m apart Do NOT operate wit...

Page 3: ...e Step 2 Follow supplied wiring instructions See wiring instructions below Step 3 Heater must be mounted with reflector angled down Step 4 All electrical connections must be in compliance with the National Electric Code NEC and local codes for outdoor wiring Step 5 Use only wiring components UL CUL CE listed for outdoor use with IPX4 minimum rating INSTALLATION INSTRUCTIONS WIRING INSTRUCTIONS The...

Page 4: ...m minimum clearance is maintained around the heater on all 4 sides and 36 91 4cm directly in front A minimum of 6 15 24cm of clearance provided by mounting brackets is required behind the plane of the face Heater can be hung using chains or custom brackets Heater must be level but can be rotated around its horizontal axis Heater must be installed with the quartz tube horizontally level For maximum...

Page 5: ... fail prematurely Connect the side of element in like manner Close element clips over tube Replace end reflectors 11 32 OUTSIDE NUT 11 32 INSIDE NUT SNUG TO CERAMIC Visit infratech usa com for video instructions PART ELEMENT LENGTH WATTS VOLTS FITS MODELS 10 1020 E 7512 16 0 4m 750 120 W 7512 10 1050 E 1412 30 0 8m 1500 120 W 1512 10 1055 E 1424 30 0 8m 1500 240 W 1524 WD 3024 10 1085 E 2024 36 0 ...

Page 6: ...HEATERS COVERAGE AREAS INFRATECH QUARTZ TUBE ELECTRIC HEATERS are furnished with wall ceiling mount swivel brackets These brackets may be discarded when the heater is hung with chains special bracketing or when used in conjunction with our flush mount frames See sales literature and price list for full listing of models descriptions amperages and voltages At times especially when the mounting heig...

Page 7: ...ment Unless heaters are installed over 12 3 7m high it is generally recommended that all radiant heaters be mounted on an angle to assure that radiant warmth is distributed from the sides rather than straight down on the heads and shoulders of the people being warmed When outdoors hang heater under protective roof or weather cover whenever possible Even though heater is all weather construction it...

Page 8: ...cident natural disaster improper installation or improper operation unauthorized adjustments or calibrations dings dents scratches nor damages due to harsh chemicals i e cleaning products improperly applied Warrantor is not responsible for consequential or incidental damages Under no circumstances shall INFRATECH or any of its representatives be held liable for injury to any person or damage to an...