Infratech W series Installation Use & Care Instructions Download Page 5

Disconnect the power at the breaker. Remove the grill by grasping it in the middle, flex grill up and lift it off.

Unscrew and remove both end reflectors. Unhook element clips at each end of the heater and remove nuts from

end of element to remove the existing quartz tube. Carefully install the new element. Remove one nut from end

of the new element. Install wire by sliding high temperature ring terminal onto element screw and replace nut.

Use a thin 11/32" wrench to hold inside nut. Nuts must make a tight connection. Reinstall end reflectors, then

snap protective grill back in place.

REPLACEMENT ELEMENT INSTALLATION

NOTE:  Hold ceramic element firmly while tightening nut

to prevent damage to element. Nut should be 

tightened snug. A loose connection can cause the 

element to short or fail prematurely. Connect the

side of  element in like manner. Close element 

clips over tube. Replace end reflectors. 

11/32” OUTSIDE NUT

11/32” INSIDE NUT

(SNUG TO CERAMIC)

(Visit infratech-usa.com for video instructions)

PART#         ELEMENT#   LENGTH                 WATTS        VOLTS       FITS MODELS 

10-1020

E-7512          16 - ½”  (0.4m)         750

120            W-7512 

10-1050

E-1412          30"         (0.8m)         1500

120            W-1512

10-1055

E-1424

30”         (0.8m)

1500

240            W-1524/WD-3024

10-1085

E-2024          36"         (0.9m)         2000

240            W-2024/WD-4024

10-2010         E-2524          36"         (0.9m)         2500

240            W-2524/WD-5024

10-2030         E-3024          58"         (1.5m)         3000

240            W-3024/WD-6024

10-2055         E-4024          58"         (1.5m)         4000

240            W-4024

REPLACEMENT ELEMENTS - (OTHER VOLTAGES ALSO AVAILABLE)

Need help?  

To order 

replacement elements for your 

Infratech heating system, 

please contact us via phone or 

visit our website.

Consult the label located on the  

back of heater for proper watts, 

voltage, and replacement 

element part number

13-1210 

Single Element End Reflector (Set of 2)

1                        

13-1252 

Dual Element End Reflector (Set of 2)

1                        

13-1202, 13-1200, 13-1205 Body Reflector – Fits 33”(0.8m), 39” (1.0m), 61- ¼” (1.6m)

13-1242, 13-1240, 13-1245

Grill Guard

 - Fits 33”(0.8m), 39” (1.0m), 61- ¼” (1.6m)                        

Lead Wire Set - Fits 33”(0.8m), 39” (1.0m), 61- ¼” (1.6m)

13-1232, 13-1230, 13-1235  Note: Dual Element Heaters require 2 Lead Wire Sets per Heater

1

22-1151

S.S. Mounting Bracket (Set of 2)

1          

18-2295,18-2300, 18-2305  Flush Mount S.S. Frame – Fits 33”(0.8m), 39” (1.0m), 61- ¼” (1.6m)

1            

REPLACEMENT PARTS

PART#

PART DESCRIPTION

QUANTITY

5

Disconnect  the  power  at  the  breaker.  Remove  the  grill  by  grasping  it  in  the  middle,  flex  grill  up  and  lift  it  off.

 

Unscrew and remove both end reflectors. Unhook element clips at each end of the heater and remove nuts from

 

end of element to remove the existing quartz tube. Carefully install the new element. Remove one nut from end 

of the new element. Install wire by sliding high temperature ring terminal onto element screw and replace nut. 

Use a thin 11/32" wrench to hold inside nut. Nuts must make a tight connection. Close element clips over tube, 

reinstall end reflectors, then snap protective grill back in place.

 

NOTE:   Hold ceramic element firmly while tightening nut

 

 

to prevent damage to element. Nut should be 

 

tightened snug. A loose connection can cause the 

 

element to short or fail prematurely.

Disconnect the power at the breaker. Remove the grill by grasping it in the middle, flex grill up and lift it off.

Unscrew and remove both end reflectors. Unhook element clips at each end of the heater and remove nuts from

end of element to remove the existing quartz tube. Carefully install the new element. Remove one nut from end

of the new element. Install wire by sliding high temperature ring terminal onto element screw and replace nut.

Use a thin 11/32" wrench to hold inside nut. Nuts must make a tight connection. Reinstall end reflectors, then

snap protective grill back in place.

REPLACEMENT ELEMENT INSTALLATION

NOTE:  Hold ceramic element firmly while tightening nut

to prevent damage to element. Nut should be 

tightened snug. A loose connection can cause the 

element to short or fail prematurely. Connect the

side of  element in like manner. Close element 

clips over tube. Replace end reflectors. 

11/32” OUTSIDE NUT

11/32” INSIDE NUT

(SNUG TO CERAMIC)

(Visit infratech-usa.com for video instructions)

PART#         ELEMENT#   LENGTH                 WATTS        VOLTS       FITS MODELS 

10-1020

E-7512          16 - ½”  (0.4m)         750

120            W-7512 

10-1050

E-1412          30"         (0.8m)         1500

120            W-1512

10-1055

E-1424

30”         (0.8m)

1500

240            W-1524/WD-3024

10-1085

E-2024          36"         (0.9m)         2000

240            W-2024/WD-4024

10-2010         E-2524          36"         (0.9m)         2500

240            W-2524/WD-5024

10-2030         E-3024          58"         (1.5m)         3000

240            W-3024/WD-6024

10-2055         E-4024          58"         (1.5m)         4000

240            W-4024

REPLACEMENT ELEMENTS - (OTHER VOLTAGES ALSO AVAILABLE)

Need help?  

To order 

replacement elements for your 

Infratech heating system, 

please contact us via phone or 

visit our website.

Consult the label located on the  

back of heater for proper watts, 

voltage, and replacement 

element part number

13-1210 

Single Element End Reflector (Set of 2)

1                        

13-1252 

Dual Element End Reflector (Set of 2)

1                        

13-1202, 13-1200, 13-1205 Body Reflector – Fits 33”(0.8m), 39” (1.0m), 61- ¼” (1.6m)

13-1242, 13-1240, 13-1245

Grill Guard

 - Fits 33”(0.8m), 39” (1.0m), 61- ¼” (1.6m)                        

Lead Wire Set - Fits 33”(0.8m), 39” (1.0m), 61- ¼” (1.6m)

13-1232, 13-1230, 13-1235  Note: Dual Element Heaters require 2 Lead Wire Sets per Heater

1

22-1151

S.S. Mounting Bracket (Set of 2)

1          

18-2295,18-2300, 18-2305  Flush Mount S.S. Frame – Fits 33”(0.8m), 39” (1.0m), 61- ¼” (1.6m)

1            

REPLACEMENT PARTS

PART#

PART DESCRIPTION

QUANTITY

5

Disconnect the power at the breaker. Remove the grill by grasping it in the middle, flex grill up and lift it off.

Unscrew and remove both end reflectors. Unhook element clips at each end of the heater and remove nuts from

end of element to remove the existing quartz tube. Carefully install the new element. Remove one nut from end

of the new element. Install wire by sliding high temperature ring terminal onto element screw and replace nut.

Use a thin 11/32" wrench to hold inside nut. Nuts must make a tight connection. Reinstall end reflectors, then

snap protective grill back in place.

REPLACEMENT ELEMENT INSTALLATION

NOTE:  Hold ceramic element firmly while tightening nut

to prevent damage to element. Nut should be 

tightened snug. A loose connection can cause the 

element to short or fail prematurely. Connect the

side of  element in like manner. Close element 

clips over tube. Replace end reflectors. 

11/32” OUTSIDE NUT

11/32” INSIDE NUT

(SNUG TO CERAMIC)

(Visit infratech-usa.com for video instructions)

PART#         ELEMENT#   LENGTH                 WATTS        VOLTS       FITS MODELS 

10-1020

E-7512          16 - ½”  (0.4m)         750

120            W-7512 

10-1050

E-1412          30"         (0.8m)         1500

120            W-1512

10-1055

E-1424

30”         (0.8m)

1500

240            W-1524/WD-3024

10-1085

E-2024          36"         (0.9m)         2000

240            W-2024/WD-4024

10-2010         E-2524          36"         (0.9m)         2500

240            W-2524/WD-5024

10-2030         E-3024          58"         (1.5m)         3000

240            W-3024/WD-6024

10-2055         E-4024          58"         (1.5m)         4000

240            W-4024

REPLACEMENT ELEMENTS - (OTHER VOLTAGES ALSO AVAILABLE)

Need help?  

To order 

replacement elements for your 

Infratech heating system, 

please contact us via phone or 

visit our website.

Consult the label located on the  

back of heater for proper watts, 

voltage, and replacement 

element part number

13-1210 

Single Element End Reflector (Set of 2)

1                        

13-1252 

Dual Element End Reflector (Set of 2)

1                        

13-1202, 13-1200, 13-1205 Body Reflector – Fits 33”(0.8m), 39” (1.0m), 61- ¼” (1.6m)

13-1242, 13-1240, 13-1245

Grill Guard

 - Fits 33”(0.8m), 39” (1.0m), 61- ¼” (1.6m)                        

Lead Wire Set - Fits 33”(0.8m), 39” (1.0m), 61- ¼” (1.6m)

13-1232, 13-1230, 13-1235  Note: Dual Element Heaters require 2 Lead Wire Sets per Heater

1

22-1151

S.S. Mounting Bracket (Set of 2)

1          

18-2295,18-2300, 18-2305  Flush Mount S.S. Frame – Fits 33”(0.8m), 39” (1.0m), 61- ¼” (1.6m)

1            

REPLACEMENT PARTS

PART#

PART DESCRIPTION

QUANTITY

5

PART# 

ELEMENT#  LENGTH 

WATTS 

VOLTS 

FITS MODELS 

10-1020  E-7512 

16½” (0.4m)  750 

120 

W-7512

10-1050  E-1412  30” (0.8m)  1500  120  W-1512
10-1055  E-1424  30” (0.8m)  1500  240  W-1524/WD-3024
10-1085  E-2024  36” (0.9m)  2000  240  W-2024/WD-4024
10-2010  E-2524  36” (0.9m)  2500  240  W-2524/WD-5024
10-2030  E-3024  58” (1.5m)  3000  240  W-3024/WD-6024
10-2055  E-4024  58” (1.5m)  4000  240  W-4024

11/32” OUTSIDE NUT

11/32” INSIDE NUT

(SNUG TO CERAMIC)

Summary of Contents for W series

Page 1: ...TABLE OF CONTENTS Warnings 2 Installation Instructions 3 Wiring Instructions 3 Mounting Instructions 4 Replacement Element Installation 5 Replacement Parts 5 Heater Coverage Areas 6 General Notes 6 Maintenance Instructions 6 Trouble Shooting 7 Location Suggestions 7 Warranty 8 ...

Page 2: ...nward angle of 30 to 60 degrees For Ceiling Mounting do not install heater closer than 18 45 7cm from adjacent walls and 6 15 2cm from ceiling and do not install less than 6 1 8 m if the heater is labeled as UL Listed and 8 2 4m if the heater is labeled as UL CUL Listed from floor while heater is at a maximum 30 degrees Adjacent Heaters to be installed no less than 3 0 9 m apart Do NOT operate wit...

Page 3: ...e Step 2 Follow supplied wiring instructions See wiring instructions below Step 3 Heater must be mounted with reflector angled down Step 4 All electrical connections must be in compliance with the National Electric Code NEC and local codes for outdoor wiring Step 5 Use only wiring components UL CUL CE listed for outdoor use with IPX4 minimum rating INSTALLATION INSTRUCTIONS WIRING INSTRUCTIONS The...

Page 4: ...m minimum clearance is maintained around the heater on all 4 sides and 36 91 4cm directly in front A minimum of 6 15 24cm of clearance provided by mounting brackets is required behind the plane of the face Heater can be hung using chains or custom brackets Heater must be level but can be rotated around its horizontal axis Heater must be installed with the quartz tube horizontally level For maximum...

Page 5: ... fail prematurely Connect the side of element in like manner Close element clips over tube Replace end reflectors 11 32 OUTSIDE NUT 11 32 INSIDE NUT SNUG TO CERAMIC Visit infratech usa com for video instructions PART ELEMENT LENGTH WATTS VOLTS FITS MODELS 10 1020 E 7512 16 0 4m 750 120 W 7512 10 1050 E 1412 30 0 8m 1500 120 W 1512 10 1055 E 1424 30 0 8m 1500 240 W 1524 WD 3024 10 1085 E 2024 36 0 ...

Page 6: ...HEATERS COVERAGE AREAS INFRATECH QUARTZ TUBE ELECTRIC HEATERS are furnished with wall ceiling mount swivel brackets These brackets may be discarded when the heater is hung with chains special bracketing or when used in conjunction with our flush mount frames See sales literature and price list for full listing of models descriptions amperages and voltages At times especially when the mounting heig...

Page 7: ...ment Unless heaters are installed over 12 3 7m high it is generally recommended that all radiant heaters be mounted on an angle to assure that radiant warmth is distributed from the sides rather than straight down on the heads and shoulders of the people being warmed When outdoors hang heater under protective roof or weather cover whenever possible Even though heater is all weather construction it...

Page 8: ...cident natural disaster improper installation or improper operation unauthorized adjustments or calibrations dings dents scratches nor damages due to harsh chemicals i e cleaning products improperly applied Warrantor is not responsible for consequential or incidental damages Under no circumstances shall INFRATECH or any of its representatives be held liable for injury to any person or damage to an...

Reviews: