Power Consumption
The table below shows detailed information about the M2M Control CX530 device's typical power
consumption while it is running.
Typical power consumption: Device operating in normal mode
12V
24V
BAT
Device active
50
30
120
mA
Device active with Cellular on*
55
32
125
mA
idle @ -51dBm* 42G)
Device active with GPRS session*
190
100
430
mA
@ -51dBm,
Battery not charging*
Device active with GNSS on
70
35
160
mA
Mode 3
Device active with WLAN on
75
50
190
mA
Connected to AP, file transfer
over the RCH
Device active with Ethernet on
110
55
250
mA
Connected to switch, file
transfer over the RCH
Device active with RF sending
60
30
125
mA
Device active while charging
400
200
-
mA
Note:
Values marked with (*) are averaged and should be considered guidelines as they may vary
depending on the cellular signal strength.
Note:
Power consumption from the battery @ 3.8V