background image

 

W

W

M

M

-

-

1

1

1

1

2

User Manual 

Version 1.0

Infosystem Technology Corporation, Ltd. 

Serial to Ethernet Module 

Summary of Contents for WM-112

Page 1: ...W W M M 1 1 1 1 2 2 User Manual Version 1 0 Infosystem Technology Corporation Ltd Serial to Ethernet Module ...

Page 2: ...all 8 Step 1 Insert the CD and click the button 8 Step 2 Click the Link of the Page 9 Step 3 Press Next to Continue 10 Step 4 Decide the Application Directory 11 Step 5 Create the Directory if not existent 12 Step 6 Create Program s Shortcut 13 Step 7 Decide if Desktop icon needed 14 Step 8 Press Install to start installation 15 Step 9 Process Installations 16 Step 10 Finish Installation 18 B Unin...

Page 3: ...d item 23 Step 3 Configure and update your parameters 24 C By Direct Broadcast Commands 25 Command List A 25 Command List B 26 Command List C 27 6 Parameter Description 28 7 Application Notes 34 A Description 34 B Disable Firewall of Windows XP SP2 34 Step 1 Execute Windows Firewall 34 Step 2 Close the Firewall 35 C Make Program exception for Firewall 36 Step 1 Choose Exception 36 Step 2 Add on Ne...

Page 4: ... for any inaccuracies that may be contained in this document Infosystem makes no commitment to update or to keep current the information contained in this manual Infosystem reserves the right to make improvements to this document and or product at any time without notice No part of this publication may be reproduced stored in a retrieval system or transmitted in any form of or by any means electro...

Page 5: ...erial to Ethernet Module Warranty All products manufactured by Infosystem are warranted against defective materials for a period of one year from the date of delivery to the original purchaser Trademark The names used for identification only maybe registered trademark of their respective companies ...

Page 6: ... to handle TCP IP stack and brings the user a lower cost TCP IP stack with limited functions because of the limited resources WM 112 is a small size and low cost module solution It is easy to implement applications in IA Factory Automation Security or any other low data rate data transmission by using it as the coprocessor It supports ARP ICMP TCP UDP IP DHCP Client and even HTTP protocols It supp...

Page 7: ...d High Reliability 9 Cheap and stable 9 Working 24Hours per day Low Power Consumption 9 Less than 1W Power Consumption Support Necessary Network Protocols 9 ARP ICMP TCP UDP IP DHCP Client HTTP Support Various Interfaces Universal Set 9 RJ 45 x 1 10 100M Auto MDI MDIX 9 Serial Port x 1 115 2Kbps RTS CTS H W flow control 9 RS 232 RS 485 RS 422 Software Configurable Half Duplex for RS485 Full Duplex...

Page 8: ... Data collection Security Terminals Access Control Terminals Security Devices Time Recorders Warehouse Terminals Shop floor automation Terminals Remote Sensors and Various Meters Power monitors Power meters Environmental monitors Temperature monitors Data loggers Data Acquisitions Auto ID Scanners Barcode Scanners Magnetic Card Readers ...

Page 9: ...Module WM 112 Serial to Ethernet Module Exterior A Top View B PIN Assignment WM 112 Module TPRX 1 TPRX 2 VCC 3 LED_LINK 4 LED_RX 5 LED_TX 6 LED_SYS 7 GND 8 TPTX 9 TPTX 10 SHIELD 11 IO6 12 ISP SETUP 13 IO5 RS485 14 RST 15 IO0 16 IO1 17 IO2 18 RXD 19 TXD 20 RTS 21 CTS 22 IO3 23 IO4 24 ...

Page 10: ...ile power on do self test 3 Low while error or restored factory default parameter 8 GND P GND DC power 9 TPTX O This is AUI transmit output pair contains the differential line drivers which send Manchester encoded data to the MAU 10 TPTX O Same as Pin 9 it is the Positive differentials transmit out 11 SHIELD GND P The shield GND 12 IO6 Hal_Duplex I O Digital I O or it is a half duplex control of t...

Page 11: ...e Installation A Installation Step 1 Insert the CD and click the button The Software Installation CD that came with EIO A 200 will automatically be run after inserting it into the CD ROM drive Click the Ethernet converter Setup Utilities button will bring the installation page out Figure1 Software Install CD Auto Run Screen Shot ...

Page 12: ...Serial to Ethernet Module WM 112 Serial to Ethernet Module Software Installation A Installation Step 2 Click the Link of the Page Click the Link of the Page to run the Ethernet Converter Setup Tools Installation Software Figure2 Ethernet Converter Setup Tools Page ...

Page 13: ...07 Infosystem Technology Corporation Ltd 10 WM 112 Serial to Ethernet Module WM 112 Serial to Ethernet Module Software Installation A Installation Step 3 Press Next to Continue Figure3 Installation Welcome Message ...

Page 14: ...system Technology Corporation Ltd 11 WM 112 Serial to Ethernet Module WM 112 Serial to Ethernet Module Software Installation A Installation Step 4 Decide the Application Directory Figure4 Decide the Application Directory ...

Page 15: ...system Technology Corporation Ltd 12 WM 112 Serial to Ethernet Module WM 112 Serial to Ethernet Module Software Installation A Installation Step 5 Create the Directory if not existent Figure5 Create Application Directory ...

Page 16: ...t 2007 Infosystem Technology Corporation Ltd 13 WM 112 Serial to Ethernet Module WM 112 Serial to Ethernet Module Software Installation A Installation Step 6 Create Program s Shortcut Figure6 Shortcut Creation ...

Page 17: ...07 Infosystem Technology Corporation Ltd 14 WM 112 Serial to Ethernet Module WM 112 Serial to Ethernet Module Software Installation A Installation Step 7 Decide if Desktop icon needed Figure7 Desktop Icon Creation ...

Page 18: ...ystem Technology Corporation Ltd 15 WM 112 Serial to Ethernet Module WM 112 Serial to Ethernet Module Software Installation A Installation Step 8 Press Install to start installation Figure8 Review the Installation Settings ...

Page 19: ...pyright 2007 Infosystem Technology Corporation Ltd 16 WM 112 Serial to Ethernet Module WM 112 Serial to Ethernet Module Software Installation A Installation Step 9 Process Installations Figure9 Installing ...

Page 20: ...t 2007 Infosystem Technology Corporation Ltd 17 WM 112 Serial to Ethernet Module WM 112 Serial to Ethernet Module Software Installation A Installation Step 10 Finish Installation Figure10 Installation Finished ...

Page 21: ...o Ethernet Module Software Installation B Uninstall Step 1 Execute Uninstall Program Uninstall Program is located at the application directory named Uninstall Ethernet Converter Setup Execution of it could let the Ethernet Converter Setup Tools clearly be removed Figure11 Decide the Application Directory ...

Page 22: ...Technology Corporation Ltd 19 WM 112 Serial to Ethernet Module WM 112 Serial to Ethernet Module Software Installation B Uninstall Step 2 Click Yes to process Figure12 Process Uninstall Step 3 Finished Figure12 Process Uninstall ...

Page 23: ...WM 112 Serial to Ethernet Module WM 112 Serial to Ethernet Module Copyright 2007 Infosystem Technology Corporation Ltd 20 Configuration A By Browser Step 1 Ready to login ...

Page 24: ...WM 112 Serial to Ethernet Module WM 112 Serial to Ethernet Module Copyright 2007 Infosystem Technology Corporation Ltd 21 Configuration A By Browser Step 2 Configure your parameters ...

Page 25: ...WM 112 Serial to Ethernet Module WM 112 Serial to Ethernet Module Copyright 2007 Infosystem Technology Corporation Ltd 22 Configuration A By Browser Step 3 Finish and reboot ...

Page 26: ...rial to Ethernet Module WM 112 Serial to Ethernet Module Copyright 2007 Infosystem Technology Corporation Ltd 23 Configuration B By Setup Tools Step 1 Searching the devices Step 2 Double click the selected item ...

Page 27: ...WM 112 Serial to Ethernet Module WM 112 Serial to Ethernet Module Copyright 2007 Infosystem Technology Corporation Ltd 24 Configuration B By Setup Tools Step 3 Configure and update your parameters ...

Page 28: ...application software Command List A User Level Command Description Notes Purpose For Broadcast search Syntax X magic code Magic code 99 130 83 99 Return AX MAC IP Device ID Send X 99 130 83 99 X or x Example Back AX 0 128 200 255 251 242 192 168 1 1 1 Purpose Get all the parameters of the WM 112 Syntax G MAC IP Setup Password Return All the parameters of the WM 112 Send G 0 128 200 255 251 242 192...

Page 29: ...y Default Setting Command List B User Level Command Description Notes Purpose Set the parameters of WM 112 Syntax S MAC IP Password Parameter Value A for accept Return C for cancel Send S 0 128 200 255 251 242 192 168 1 1 123 IP 192 168 1 2 S Example Back A or C Purpose Reboot WM 112 Syntax R MAC IP Setup Password AR for accept Return CR for cancel Send R 0 128 200 255 251 242 192 168 1 1 123 R Ex...

Page 30: ... Command List C Admin Level Command Description Notes Purpose Set MAC of WM 112 then reboot automatically Syntax M Old MAC New MAC Factory Password AM for accept Return CM for cancel Send S 0 128 200 255 251 242 0 128 200 255 251 243 123 M Example Back A or C Purpose Set IP for Factory settings Syntax I MAC New IP Factory Password AI for accept Return CI for cancel Send I 0 128 200 255 251 242 192...

Page 31: ...255 255 255 0 for Class C IP Ask your network administrator for assistance if in doubt Gateway IP The IP address of the router The default Gateway IP address is 192 168 1 254 Ask your network administrator for assistance if in doubt DHCP Client If this option is enabled that means the IP address Subnet mask and Gateway IP address of the WM 112 converter are set dynamically by the DHCP Server If th...

Page 32: ...lient device TCP Client The WM 112 converter will operate at the Active or the TCP Active mode to request establishing a TCP connection with the remote server device UDP Server The WM 112 converter will operate at the UDP Server mode to send and receive UDP datagram to from the remote device UDP Client The WM 112 converter will operate at the UDP Client mode to send and receive UDP datagram to fro...

Page 33: ... to 115200 Parity None Even or odd Data Bits 7 or 8 Stop Bit 1 or 2 SIO Type Type of serial I O The serial interface types RS232 RS232 with RTS CTS control RS232 with RTS CTS DSR DTR control RS485 half duplex mode RS422 full duplex mode SIO Packets Gap SIO Inter Character Gap In some cases for example if the Modbus RTU serial protocol is used the completion of the message packet in the input buffe...

Page 34: ...UDP client mode the Remote Host IP address must be specified to establish the connection with the designated HOST server only Remote Host Port If the WM 112 converter is used in TCP client mode or UDP client mode the Host Port No must be specified This is the port which the Remote Host IP listens for incoming data Slave Response Time Out Expected Time Out for the response of slave machines Device ...

Page 35: ...cted by the WM 112 converter if there is no further TCP activity within the given timeout value Command Port The WM 112 converter supports the command mode which user can use to setup the parameters or get the information of the converter with UDP protocol from the remote host The default Command Port number is 65535 The command port of the WM 112 converter should be set correctly while using the ...

Page 36: ...up password text box blank Access password If this password is configured the remote host needs to send this access password one second periodically to the Check Status Port of the WM 112 converter otherwise the data transfer request will not be accepted by the WM 112 converter To erase an existing password just leave the Access password text box blank Multi Sockets Arbitration Time Period Arbitra...

Page 37: ... Serial to Ethernet Module Application Notes A Description Firewall will make the program off normal so one might choose the following solutions to Firewall program Disable or Exception B Disable Firewall of Windows XP SP2 Step 1 Execute Windows Firewall Execute Windows Firewall in Control Panel ...

Page 38: ...nfosystem Technology Corporation Ltd 35 WM 112 Serial to Ethernet Module WM 112 Serial to Ethernet Module Application Notes B Disable Firewall of Windows XP SP2 Step 2 Close the Firewall Choose Close to close firewall ...

Page 39: ...Corporation Ltd 36 WM 112 Serial to Ethernet Module WM 112 Serial to Ethernet Module Application Notes C Make Program exception for Firewall Step 1 Choose Exception Choose Exception in Firewall Program And add on new program of Setup Tools ...

Page 40: ...ology Corporation Ltd 37 WM 112 Serial to Ethernet Module WM 112 Serial to Ethernet Module Application Notes C Make Program exception for Firewall Step 2 Add on New Program and Selection Choose Setup Tools to make it as an exception ...

Page 41: ...echnology Corporation Ltd 38 WM 112 Serial to Ethernet Module WM 112 Serial to Ethernet Module Application Notes C Make Program exception for Firewall Step 3 Allow Accept Any Computer Allow Accept Any Computer to finish exception ...

Page 42: ...right 2007 Infosystem Technology Corporation Ltd 39 WM 112 Serial to Ethernet Module WM 112 Serial to Ethernet Module Application Notes C Make Program exception for Firewall Step 4 Finished Finish Exception ...

Page 43: ...XD 20 RTS 21 CTS 22 IO3 23 IO4 24 RX D RX D TX TX TPRX LED_LNK LED_TX LED_RX LED_SYS TPTX TPTX R4 75 R5 75 R6 75 IO4 C11 1000P 2KV C16 1000P 2KV RTS CTS IO3 IO2 IO1 RXD TXD RS485 RS232SELEC IO0 J5 RJ45 TX 1 TX 2 RX 3 4 4 5 5 RX 6 7 7 8 8 TPRX FG FG VCC C8 10uF S2 SW PB ETHERNET PORT RS 422 485 PORT RS 232 PORT 5V POWER WM 112 MODULE S1 SW PB U5 DS75176B RO 1 RE 2 DE 3 DI 4 GND 5 DO RI 6 DO RI 7 VC...

Page 44: ...FAX 886 3 561 1435 Service E mail services infosystem com tw Web page URL http www infosystem com tw Infosystem Copyright 2007 Infosystem Technology Corporation Ltd No 45 Lane 167 Dongnan St Hsinchu Taiwan 300 R O C TEL 886 3 562 7187 FAX 886 3 561 1435 Service E mail services infosystem com tw Web page URL http www infosystem com tw ...

Reviews: