Page 12
Copyright © 2016 InfoSight Corporation All Rights Reserved
KE-28XX InfoTag
®
Marker
╔══════════════[ InfoSight Corporation - InfoTag Marking System ]══════════════╗
║╔══════════════════════════════[ Tag Editor ]══════════════════════════════╗ ║
║║ ╔══════════════════════[ Operator Setup Editor ]═════════════════════╗ ║ ║
╠║ ║ ║ ║ ═╣
║║ 1║ Active Prompt Verify Auto Clear ║ ║ ║
║║ 2║ 1 : [X] [HEAT # : ] [####### ] [X] ║ ║ ╗║
║║ 3║ 2 : [X] [SEQ NUM: ] [## ] [X] ║ ║ ║║
║║ 4║ 3 : [ ] [ ] [ ] [ ] ║ ║ ║║
║║ 5║ 4 : [ ] [ ] [ ] [ ] ║ ║ ║║
║║ 6║ 5 : [ ] [ ] [ ] [ ] ║ ║ ║║
║║ 7║ 6 : [ ] [ ] [ ] [ ] ║ ║ ║║
║║ 8║ 7 : [ ] [ ] [ ] [ ] ║ ║ ║║
║║ ║ 8 : [ ] [ ] [ ] [ ] ║ ║ ║║
║║ ║ ║ ║ ║║
║║ ║ Qty Req [X] [START NO: ][X] Lower [ ] Upper [ ] ║ ║ ║║
║║ ║ ║ ║ ║║
║║ ║ ╔══════════╗ ╔══════════╗ ╔══════════╗ ║ ║ ║║
║║ ║ ║ Ok ║ ║ DEFAULT ║ ║ Cancel ║ ║ ║ ║║
║║ ║ ╚══════════╝ ╚══════════╝ ╚══════════╝ ║ ║ ╝║
║║║ ╚════════════════════════════════════════════════════════════════════╝ ║ ║
║║╚═ ║ ║
║╚══════════════════════════════════════════════════════════════════════════╝ ║
║ ║
╚══════════════════════════════════════════════════════════════════════════════╝
There are 8 available prompt fields. The prompts in this example are explained below.
The first line will print HEAT # : on the OPERATOR SCREEN and limit the operator to entering
only 4 numbers.
The second line will print SEQ NUM: on the OPERATOR SCREEN and limit the operator to
entering only 2 numbers.
Both will auto clear once the operator starts to type.
The following describes each heading:
ACTIVE - Toggle field (RETURN). Makes prompt show up on OPERATOR SCREEN
PROMPT - Up to a 10 character messages for each prompt.
VERIFY - Verifies information typed is accurate using special characters:
$ - Alpha Upper Case Characters (A,B,C,D...)
# - Numeric Digits (1,2,3,4...)
? - Any Character (A,B,C,1,2,3,?,/,%...)
* - Any Character for any length up to the next instruction.
[ ] -The Characters in the brackets are the only valid characters, exactly as typed.
AUTO CLEAR - Clears the data field when the operator starts to type in the data.
Also causes a clear after each cycle print completed
At the bottom of the OPERATOR SETUP SCREEN has 3 prompts; OK, CANCEL, DEFAULTS.
The following explains each:
OK - Returns to the EDIT SCREEN and saves the operator input layouts.
CANCEL - Returns to the EDIT SCREEN without saving the operator layouts.