User Manual for V2.8
–
2/21/2020
16
4.
General Operations
4.1 Menu Operations
The menu can be accessed by pressing the left button
<
Menu
> on the Startup Screen. Menu list is displayed in
Figure 10. The left key is used to scroll through the
options.
To select, bring desired option to the top line by using left
key and press right button <
Select
>. A test can be started
by returning to the startup screen by pressing the center
button <
Return
>.
To return to menu after selecting an item, press the center
button <
Return
>. Each option is described below, and is
available on both TX and RX, unless noted otherwise:
Data Synch
: (RX Only) Initiates data synchronization between the TX and RX, if they are in communication
range of each other
(less than 50’ and free of obstructions between) and should remain close while the
transfer takes place). Once the transfer is completed, both displays will automatically return to the Startup
screen. The time required for data synchronization depends on the number of measurements conducted
since the last synchronization. We recommend Data Synch to be conducted at least once every 10
measurements. Synchronization allows measurements to be validated. Table 2 lists the possible outcomes
for the measurement validation process and the measurement condition which causes the outcome.
Table 2. Data Synch Status and descriptions
Verify Operation
: Provides method for verifying the TX and RX functional operation. The test is conductied
with the TX tone sequence at a lower sound pressure level (-16 dB from normal test). To conduct a Verify
Operation Test
–
the TX and RX should be located within one foot of each other. To start the test select
Verify Operations on first the TX and then the RX .
Measurement
Status
Condition
Valid
No anomalies in the measurement conditions were detected
Early
The SL-RAT transmitter unit (TX) was stopped prior to the SL-RAT receiving
unit (RX) completed its processing. The Pipe assessment may be corrupted.
Late
The SL-RAT transmitter unit (TX) was started after the SL-RAT receiving unit
(RX). The Pipe assessment may be corrupted.
No TX
The SL-RAT transmitter unit (TX) was not turned on during SL-RAT receiving
unit (RX) measurement.
The Pipe assessment is corrupted.
Fig 10 -
The Menu can be accessed by
pressing the left button, <Menu>, on the