background image

INFOSEC UPS SYSTEM - 15, rue du Moulin - 44880 Sautron - FRANCE -  www.infosec-ups.com 

Hot Line 

– Tel + 33 (0)2 40 76 15 82 - Fax + 33 (0)2 40 94 29 51 - [email protected] – 08 19 AA 59 205 06 

User guide 

 

To ensure this product is correctly installed and used appropriately, we highly advise you to 
read this user guide very carefully. 

 
1 .   I N T R O D U C T I O N  

 

Designed to be extremely efficient and user-friendly, R1 USB is the perfect  AVR to protect 
your sensitive electronic equipment. 
 

2 .   M A I N   C H A R A C T E R I S T I C S  

 

  Accepts wide input voltage range through boost and buck stabilizer 

  Provides stable output voltage  

  3 FR/SCHUKO outlets 

  1 USB charger 

  Provides over-/under-voltage protection 

  Provides Over-temperature protection 

  Compact size 

  Wall mounting system 

 
3 .   S A F E T Y   I N S T R U C T I O N S  

–   S e c u r i t y  

 

 

Risk of Electric Shock:

 

 

The AVR unit uses potentially hazardous voltages. Do not attempt to disassemble this 

equipment as it does not contain accessible components that can be repaired by users.  

 

All repairs should be performed by qualified technicians only. 

 

The utility power outlet shall be near the equipment and easily accessible. To isolate 

the AVR from AC input, remove the plug from the utility power outlet. 

 

Install the AVR in a temperature and humidity-controlled indoor area free of conductive 

interference. 

 

It  should  not  be  exposed  to  direct  sunlight  or  sources  of  heat.  Do  not  cover  the 

ventilation slots. 

 

Disconnect the  AVR from AC power  before cleaning with  a damp cloth (no cleaning 

products). 

 

In an emergency situation, switch the AVR 

to the “Off” position and disconnect the unit 

from the AC power supply. 

 

When the AVR 

is out of order, please refer to “

section 9: trouble shooting

” and call 

the hot line. 

 
 

 

Connected products: 

 

Make sure that the connected load does not exceed AVR capabilities. Do not leave any 

recipients containing liquid on or near the AVR. 

 

Do not plug the AVR input into its own output socket. 

 

Do not plug the AVR into a power strip or surge suppressor. 

 

The  AVR  has  been  designed  for  sensitive  equipments.  It  should  not  be  used  with 

equipment with inductive loads such as motors. 

 

Do  not  connect  any  household  appliances  such  as  vacuum  cleaners  or  life-support 

systems to the AVR. 

 

Due to excessive consumption, laser printers should not be connected to the AVR. 

 

When use the voltage regulator with an Uninterruptible Power Supply (UPS), connect 

the UPS to the output of this product, then connect the product to the wall outlet. 

Summary of Contents for R1 USB 1000

Page 1: ...MANUEL UTILISATEUR USER S MANUAL Notice d utilisation __________ 2 User guide _________________ 9 Gu a del usuario ___________ 15 Bedienungsanleitung________ 20 ________________ 28 600 1000 1500 VA...

Page 2: ...n personnel qualifi L quipement doit tre plac pr s de la prise de courant et celle ci doit tre facilement accessible Pour d sactiver compl tement l appareil d brancher le c ble d alimentation de l app...

Page 3: ...es quipements lectroniques domestiques comme une t l vision une cha ne st r o un lecteur CD un magn toscope ou un lecteur de DVD un appareil de traitement des donn es un modem une machine crire une ca...

Page 4: ...crits sur la plaque signal tique l arri re de l appareil Vous pouvez galement les reporter dans le cadre ci dessous Mod le Num ro de s rie Date d achat R1 USB Veuillez conserver l emballage d origine...

Page 5: ...4 29 51 hotline infosec fr 08 19 AA 59 205 06 5 6 D E S C R I P T I O N VUE D ENSEMBLE DU R1 USB Interrupteur d alimentation C ble d entr e int gr Prises de sortie protection AVR type FR SCHUKO Port U...

Page 6: ...ls afin d viter les interf rences 3 Connexion V rifier sur la plaque signal tique que la tension d alimentation est compatible avec celle du r seau et que la puissance de l appareil est suffisante pou...

Page 7: ...ntage horizontal Montage vertical 9 D E P A N N A G E Dans le cas o le r gulateur ne fonctionnerait pas correctement nous vous recommandons d effectuer les tests suivants avant d appeler le Service Ap...

Page 8: ...0 230 240 VCA Plage de tension 184 284 VCA Fr quence 50 Hz ou 60 Hz OUTPUT Tension 220 230 240 VCA R gulation de tension 10 Sorties 3 prises protection ACS FR SCHUKO Chargeur USB 5 V CC 0 5 A VOYANT L...

Page 9: ...sily accessible To isolate the AVR from AC input remove the plug from the utility power outlet Install the AVR in a temperature and humidity controlled indoor area free of conductive interference It s...

Page 10: ...ment such as a home computer monitor inkjet printer scanner or fax It is also designed for use with home electronics equipment such as television stereos CD players VCRs and DVD players data processin...

Page 11: ...ical information you require on your guarantee or on the identification plate on the back of the unit If convenient you may enter the details in the following box Model Serial number Date of purchase...

Page 12: ...Fax 33 0 2 40 94 29 51 hotline infosec fr 08 19 AA 59 205 06 12 6 D E S C R I P T I O N R 1 U S B O V E R V I E W Power switch Integrated input cable AVR protected output receptacles FR SCHUKO type 5V...

Page 13: ...the unit away from other units at least 2 5cm to avoid interference 3 Connection Check the identification plate to make sure that the power supply is compatible with network voltage and that the devic...

Page 14: ...Is the AVR overloaded 1 0 T E C H N I C A L S P E C I F I C A T I O N S Model R1 USB 600 R1 USB 1000 R1 USB 1500 CAPACITY 600VA 300W 1000VA 500W 1500VA 750W INPUT Voltage 220 230 240 VAC Voltage Range...

Page 15: ...uipo y ser de f cil acceso Para aislar el regulador autom tico de voltaje de la entrada de CA desench felo del tomacorriente Instale el regulador autom tico de voltaje en un rea cubierta con temperatu...

Page 16: ...mo una computadora del hogar una impresora un esc ner o un fax Tambi n se dise a para usar con equipo electr nico para el hogar como televisi n est reos reproductores de CD VCR y DVD equipo de procesa...

Page 17: ...informaci n t cnica que necesita en su garant a o en la placa de identificaci n en la parte posterior de la unidad Si es conveniente puede escribir los detalles en el siguiente recuadro Modelo N mero...

Page 18: ...rde LED de AVR luz amarilla LED de falla luz roja Para utilizar con enchufes CEE 7 7 FR Schuko 7 I N S T A L A C I N Y O P E R A C I N 1 Verificaci n Al recibir su equipo abra el paquete y verifique q...

Page 19: ...ico de voltaje 4 Encendido Apagado Encienda la unidad al presionar el interruptor de energ a en la posici n RESTABLECER Luego todos los dispositivos se encender n Para encender el regulador autom tico...

Page 20: ...de los valores espec ficos de la unidad El regulador autom tico de voltaje est sobrecargado 1 0 E S P E C I F I C A C I O N E S T C N I C A S Modelo R1 USB 600 R1 USB 1000 R1 USB 1500 CAPACIDAD 600 VA...

Page 21: ...zsteckdose muss sich nahe am Ger t befinden und leicht zug nglich sein Zum Trennen der AVR vom Stromnetz ziehen Sie den Stecker aus der Netzsteckdose Installieren Sie die AVR in einem Raum mit Tempera...

Page 22: ...pannungsregler wurde f r den Gebrauch von spannungsempfindlicher Ausr stung entworfen z B PC Bildschirm Tintenstrahldrucker Scanner oder Faxger t Er wurde ebenfalls f r den Gebrauch von Unterhaltungse...

Page 23: ...Informationen auf der Garantiekarte oder auf der Datenplakette an der R ckseite des Ger tes Wir empfehlen die Details im folgenden K stchen zu notieren Modell Seriennummer Kaufdatum R1 USB Bitte hebe...

Page 24: ...15 82 Fax 33 0 2 40 94 29 51 hotline infosec fr 08 19 AA 59 205 06 24 6 B E S C H R E I B U N G R1 USB BERBLICK Netzschalter Integriertes Eingangskabel AVR gesch tzte Ausgangsbuchsen Typ FR SCHUKO 5V...

Page 25: ...um St rungen zu vermeiden 3 Anschl sse Vergewissern Sie sich anhand der Datenplakette dass die Stromversorgung mit dem Stromnetz kompatibel ist und die Leistung der Anlage ausreicht Schlie en Sie die...

Page 26: ...59 205 06 26 9 S T R U N G S B E H E B U N G Falls die AVR nicht einwandfrei arbeitet empfehlen wir die folgenden Tests vorzunehmen bevor Sie sich an die Hotline wenden Checkliste Ist der Hauptschalt...

Page 27: ...240 VAC Spannungsbereich 184 284 VAC Frequenz 50 Hz oder 60 Hz AUSGANG Spannung 220 230 240 VAC Spannungsregulierung 10 Steckdosen 3 USV gesch tzte FR SCHUKO Steckdosen USB Ladeger t 5V DC 0 5A ANZEIG...

Page 28: ...SEC UPS SYSTEM 15 rue du Moulin 44880 Sautron FRANCE www infosec ups com Hot Line Tel 33 0 2 40 76 15 82 Fax 33 0 2 40 94 29 51 hotline infosec fr 08 19 AA 59 205 06 28 1 R1 USB 2 3 FR SCHUKO USB 3 OF...

Page 29: ...INFOSEC UPS SYSTEM 15 rue du Moulin 44880 Sautron FRANCE www infosec ups com Hot Line Tel 33 0 2 40 76 15 82 Fax 33 0 2 40 94 29 51 hotline infosec fr 08 19 AA 59 205 06 29 50 VCR DVD 4 40 0 90 5...

Page 30: ...INFOSEC UPS SYSTEM 15 rue du Moulin 44880 Sautron FRANCE www infosec ups com Hot Line Tel 33 0 2 40 76 15 82 Fax 33 0 2 40 94 29 51 hotline infosec fr 08 19 AA 59 205 06 30 R1 USB CE EMC LVD...

Page 31: ...du Moulin 44880 Sautron FRANCE www infosec ups com Hot Line Tel 33 0 2 40 76 15 82 Fax 33 0 2 40 94 29 51 hotline infosec fr 08 19 AA 59 205 06 31 6 R1 USB FR SCHUKO USB 5 LED LED CEE 7 7 7 1 R1 USB...

Page 32: ...SYSTEM 15 rue du Moulin 44880 Sautron FRANCE www infosec ups com Hot Line Tel 33 0 2 40 76 15 82 Fax 33 0 2 40 94 29 51 hotline infosec fr 08 19 AA 59 205 06 32 20 CPU 2 5 3 4 RESET 8 1 114 2 1 3 2 3...

Page 33: ...33 0 2 40 76 15 82 Fax 33 0 2 40 94 29 51 hotline infosec fr 08 19 AA 59 205 06 33 9 ON 10 R1 USB 600 R1 USB 1000 R1 USB 1500 600 300 1000 500 1500 750 220 230 240 184 284 50 60 220 230 240 10 3 UPS F...

Reviews: