7 . I N S T A L L A T I O N A N D O P E R A T I O N
1. Control
When you receive your equipment, open the packaging and check that your UPS has not
been damaged. The packaging includes : a UPS unit, a user’s guide, a power cable, 3 IEC
output cables, 1 RJ11 cable. In case of damage, please submit a standard claim to the after-
sales service.
2. Charging
This unit is shipped from the factory with its internal battery fully charged, however, some
charge may be lost during shipping and the battery should be recharged prior to use. Plug
the unit into an appropriate power supply and allow the UPS to charge fully by leaving it
plugged-in for at least 8 hours with no load.
3. Place and installation
The UPS has been designed to operate in a protected environment, at temperatures
between 0° C and 40° C and at a rate of humidity ranging between 0 % and 90% (no
condensation).
Do not obstruct the ventilation grills. Install the unit in an environment which is free from
dust, chemical vapours and conductors.
Moreover, in order to avoid any interference, keep the UPS at least 20 cm away from the
CPU (central processing unit).
4.
Connection
Plug the UPS into a 2-pole, 3-wire grounded receptacle. Then connect one computer-related
device into each of the power receptacles supplied on the back of the UPS.
You can also connect a device which does not require backup time, like a printer for
example, into the surge protected and filtered outlet.
5. Turn On/Off
To turn on the UPS unit, press the power switch lightly. To turn off the UPS unit, press the
power switch again.
6. DC Start
All of the iPEL evolution units are equipped with an integrated DC start function. To start the
UPS in absence of power supply and with a full battery, press the button.
7. Green Power Function
All iPEL is equipped with Green Power Function. If no load connects to the UPS, it will
automatically shut down in 2 minutes for energy saving while power failure. The Power
switch must be kept in the ‘ON’ position, otherwise, the UPS will be disabled and your
equipment will not be protected during a power failure.
8. Free Download Software – UPSurf Control
Go to Web sit :
www.infosec.fr