background image

514mm 

20.24

787mm 

30.98

605mm 

23.81

90mm 

3.54

440mm 

17.32

ESDS 3012R
ESDS 3012RT

ESDS 3012G
ESDS 3012GT

31.2kg

68.78lbs

43.2kg

95.24lbs

496.75mm 

19.57

15.26kg

33.64lbs

569.17mm 

22.4

29.98kg

64.99lbs

41.48kg

91.45lbs

496.75mm 

19.57

14.26kg

31.44lbs

569.17mm 

22.4

*1. Shipping weight includes HDD,  spare parts and accessories packages and
       outer carton weight. All weight information are estimated numbers. The 
       actual weight may vary according to drives and configurations.

*2. System width (deep) is from the back of chassis ear to the rear-end 
       protrudings (PSU handles).  

*3. Please allow 200mm (7.87inch) at the back and 50mm (1.97inch) in front of 
       the subsystem for cabling and airflow.

Shipping Box

A

B

C

D

Shipping Guide

Package Dimensions

Net 

weight

Model

A

B

C

System Dimensions

S h i p p i n g

W e i g h t

w i t h 

S y s t e m * 1

D

E

F

G*2

System Weight

S h i p p i n g

W e i g h t

w i t h

S y s t e m

a n d  H D D 

Air

Airflow

Direction

G

E

F

System

571mm 

22.48

787mm 

30.98

605mm 

23.81

130mm 

5.12

445mm 

17.52

496.77mm 

19.57

Front to 

Rear

36.37kg

80.18lbs

52.37kg

115.46lbs

567.57mm 

22.36

20.8kg

45.86lbs

ESDS 3016R
ESDS 3016RE
ESDS 3016RTE

496.77mm 

19.57

34.53kg

76.13lbs

50.63kg

111.4lbs

567.57mm 

22.36

18.96kg

41.80lbs

ESDS 3024R
ESDS 3024RT

ESDS 3024G
ESDS 3024GT

43.36kg

95.59lbs

67.36kg

148.50lbs

496.5mm 

19.57

568.80mm 

22.40

25.7kg

56.66lbs

646mm 

25.43

787mm 

30.98

605mm 
23.81

174mm 

6.85

445mm 

17.52

41.52kg

91.54lbs

65.52kg

144.45lbs

23.86kg

52.6lbs

496.5mm 

19.57

568.80mm 

22.40

ESDS 3016G
ESDS 3016GE
ESDS 3016GTE

*1. Shipping weight includes HDD,  spare parts 
       and accessories packages and outer carton    
       weight. All weight information are estimated 
       numbers. The actual weight may vary
       according to drives and configurations.

*2. System width (deep) is from the back of   
       chassis ear to the rear-end protrudings (PSU 
       handles).  

*3. Please allow 200mm (7.87inch) at the back 
       and 50mm (1.97inch) in front of the system 
       for cabling and airflow.

Ship

pin

g

Box

A’

B

C

G

D

F

System

A

E

4

U 4

8 b
a

y

ESDS 3048RE
ESDS 3048RTE

426mm   

16.78"

670mm  

26.38"

1150mm   

45.28"

630mm   
24.80"

94.33kg   

207.15lbs

107.29kg
236.89lbs    

175.9mm   

6.92"

445mm

15.1"    

873.5mm    

34.39"

939mm   

36.97"

53.41kg

117.75lbs

Front to 

Rear

Package Dimensions

Net 

weight

Model

A

B

C

System Dimensions

S h i p p i n g

W e i g h t

w i t h 

S y s t e m * 1

D

E

F

G*2

System Weight

S h i p p i n g

W e i g h t

w i t h

S y s t e m

a n d  H D D 

Air*3

Airflow

Direction

A’

ESDS 3048GE
ESDS 3048GTE

2

U

1

2 b
a

y

3

U 1

6 b
a

y

4

U 2

4 b
a

y

16

ESDS 3060RTE
ESDS 3060GTE
ESDS 3060RE
ESDS 3060GE

4

U 6

0 b
a

y

426mm   

16.78"

670mm  

26.38"

1150mm   

45.28"

630mm   
24.80"

71.7kg   

158.07lbs

125kg
282.19lbs    

176mm   

6.93"

445.4mm

17.54"    

881.4mm    

34.7"

948.64mm   

37.35"

52kg

114.64lbs

Summary of Contents for EonStor DS 3000 Series

Page 1: ...EonStor DS 3000 Series Product Quick Reference Guide...

Page 2: ...s EonNAS Pro and EonNAS 1000 Series Benchmark Reviews awards their Golden Tachometer Award to Infortrend EonNAS 1100 Infortrend sign a distribution agreement with Russia s Merlion Infortrend EonStor D...

Page 3: ...ortrend Technology Inc All rights reserved Any information provided herein is without warranties of any kind of and is subject to change without prior notice Infortrend EonStor SANWatch and EonPath ar...

Page 4: ...le as needed via expansion enclosures Intuitive SANWatch 3 0 UI offers detailed yet easy to learn storage supervision Clearly understandable event and error messages enhance management maintenance and...

Page 5: ...SU INC x 2 9373CDTray INC x 12 9373CDHTray OPT 9373CMUX3G OPT 9370CSFP8G 8Gb FC OPT 9370CSFP16G 16Gb FC OPT 9370CSFP10G 10Gb ISCS SFP OPT 9373AYCAB INCx1 9373ASCAB OPT 9270CFCCab04 1M FC cable OPT 927...

Page 6: ...C x 16 9373CDHTray OPT 9373CMUX3G OPT 9370CSFP8G 8Gb FC OPT 9370CSFP16G 16Gb FC OPT 9370CSFP10G 10Gb ISCS SFP OPT 9373AYCAB INCx1 9373ASCAB OPT 9270CFCCab04 1M FC cable OPT 9270CFCCab05 5M FC cable OP...

Page 7: ...x 3 9370CSFP8G 8Gb FC OPT 9370CSFP16G 16Gb FC OPT 9370CSFP10G 10Gb ISCS SFP OPT 9373AYCAB INC x 1 9373ASCAB OPT 9270CFCCab04 1M FC cable OPT 9270CFCCab05 5M FC cable OPT 9270CFCCab06 10M FC cable OPT...

Page 8: ...n PSU 9373CPSU INCx2 9373CDTray INC x 12 9373CDHTray OPT 9373CMUX3G OPT 9370CSFP8G 8Gb FC OPT 9370CSFP16G 16Gb FC OPT 9370CSFP10G 10Gb ISCS SFP OPT 9373AYCAB INC x 1 9373ASCAB OPT 9270CFCCab04 1M FC c...

Page 9: ...in PSU 9373CPSU INC x 2 9373CDTray INC x 16 9373CDHTray OPT 9373CMUX3G OPT 9370CSFP8G 8Gb FC OPT 9370CSFP16G 16Gb FC OPT 9370CSFP10G 10Gb ISCS SFP OPT 9373AYCAB INC x 1 9270CFCCab04 1M FC cable OPT 92...

Page 10: ...9474FAN drawer fan INC x 3 9474LOCKERV INC x 48 9370CSFP8G 8Gb FC OPT 9370CSFP16G 16Gb FC OPT 9370CSFP10G 10Gb ISCS SFP OPT 9373AYCAB INCx1 9373ASCAB OPT 9270CFCCab04 1M FC cable OPT 9270CFCCab05 5M...

Page 11: ...270CmSASCab6 1 7M SAS cable OPT 9270CmSASCab8 1 2M SAS cable OPT 9270CmSASCab9 2 6M SAS cable OPT Model Form factor Controller Host channel1 per ctrl Drive channel1 per ctrl Hot swap cooling modules H...

Page 12: ...3016GTE 3U RAID ESDS 3024R ESDS 3024RT ESDS 3024G ESDS 3024GT ESDS 3048RE ESDS 3048RTE ESDS 3048GE ESDS 3048GTE ESDS 3060RE ESDS 3060RTE ESDS 3060GE ESDS 3060GTE 4U RAID 312 312 316 316 324 324 336 3...

Page 13: ...OUT SAS IN Link Link SAS OUT SAS IN Link Link SAS OUT SAS IN Link Link SAS OUT SAS IN Link Link SAS OUT SAS IN Link Link SAS OUT SAS IN Link Link 1st JBOD 2nd JBOD Last JBOD 1st JBOD 2nd JBOD Last JBO...

Page 14: ...ect with expansion RAID System RAID System 1st JBOD 2nd JBOD Last JBOD 1st JBOD 2nd JBOD Last JBOD 4U 48bay LFF subsystems Dual controller Single controller Refer to expansion guide for the maximum nu...

Page 15: ...ting the maximum numbers of expansion enclosures Refer to expansion guide for the maximum numbers of expansion enclosures Dual redundant controller subsystems can connect with expansion enclosures by...

Page 16: ...10Gb iSCSI RJ45 10Gb iSCSI SFP 16Gb Fibre Host board options JBOD Link 1 JBOD Link 2 JBOD Link 1 JBOD Link 1 JBOD Link 2 JBOD Link 1 JBOD 1 Link JBOD 2 Link 0 1 JBOD 1 Link 0 1 With FC iSCSI and SAS...

Page 17: ...e to pole 1 Maximum Length Pole to pole 1 609 6 mm 24 inches 914 4 mm 36 inches 762 mm 30 inches 939 8 mm 37 inches 1 The pole to pole length or post to post length refers to the distance between the...

Page 18: ...DS 3024RT ESDS 3024G ESDS 3024GT 43 36kg 95 59lbs 67 36kg 148 50lbs 496 5mm 19 57 568 80mm 22 40 25 7kg 56 66lbs 646mm 25 43 787mm 30 98 605mm 23 81 174mm 6 85 445mm 17 52 41 52kg 91 54lbs 65 52kg 144...

Page 19: ...in time differential copies without disrupting online applications Restore deleted files or roll data volume back in seconds based on space saving recovery points reate independent point in time and...

Page 20: ...of their respective owners Asia Pacific Taipei Taiwan Infortrend Technology Inc Tel 886 2 2226 0126 E mail sales ap infortrend com Americas Sunnyvale USA Infortrend Corporation Tel 1 408 988 5088 E ma...

Page 21: ...Click below to find more Mipaper at www lcis com tw Mipaper at www lcis com tw...