background image

ESDS 3048GTE

Dual-redundant

Single

4U-48bay LFF

ESDS 3060RTE

ESDS 3060GTE

Model

Form Factor

Storage Controller

Onboard GbE ports 

(per ctrl.)

Accessory Variations (INC: Included, OPT: Optional)

ESDS 3048RTE

Dual-redundant

Single

Host connectivity 

(

)

per ctrl.

Drive connectivity

Expansion Channel

(

)

*2 

per ctrl.

4U-60bay LFF

4 x 8Gb FC ports
2 x 16Gb FC ports
4 x 1Gb iSCSI ports
2 x 10Gb iSCSI ports (SFP+ or RJ-45)
2 x 6Gb SAS ports

6Gb SAS

1 x 6Gb SAS port

RAID Functions

RAID 0, 1, (0+1), 3, 5, 6,10, 30, 50, 60 with local spare, global spare, and enclosure spare drives

Multiple RAID logical drives (LD), logical volumes (LV), partitions, host IDs, host LUNs, instant RAID ready, LD configuration on disks, dynamic 

     host LUN mappings

Advanced Functions

Host-side redundant path and load balancing supported (EonPath software required in the host computers) , switched fabric support, fabric 

     log-in(supported on fibre-host model)

Dual-mode RAID expansion ""Add-in Drive"" and ""Copy & Replace with large drive" 

Redundant models: Auto-sync firmware and configuration on replacement controller

Management

LCD front panel: Easy-to-use menu for accessing all functions and features

RS-232 Terminal: User friendly menu-driven for accessing all functions and features

SANWatch: Storage management suite. (Storage management, central view, and Notification manager via e-mail, LAN broadcast, SNMP trap, 

    Skype and fax)

Management via Built-in
LAN

Embedded RAIDWatch: Storage management, event notifications (e-mail, SNMP trap, etc.) via HTTP

Telnet-terminal: User-friendly menu-driven for accessing all function and feature via telnet

Data services

Local replication (snapshot, volume copy and volume mirror)

Thin provisioning: "Just-in-time" capacity allocation optimizes storage utilization and ellimates allocated but unused storage space

Hot Swap Cooling Modules

Hot Swap Power Supplies

Cache Memory*3

Cache backup*4

3 (embedded in PSU)

3 x 530W

2GB, 4GB, 8GB or 16GB DDR-III

CBM

Controller Module 
(w/cache memory)

84SC30RI48MB (w/2GB)
84SC30RI48MC (w/2 x 2GB)
84SC30RI48MD (w/2 x 4GB)
84SC30RI48MF (w/2 x 8GB)

84SC30GI48MB (w/2GB)
84SC30GI48MC (w/2 x 2GB)
84SC30GI48MD (w/2 x 4GB)
84SC30GI48MF (w/2 x 8GB)

RFC08G0HIO4 (8Gb FC, OPT)
RFC16G0HIO2 (16Gb FC, OPT)
RER01G0HIO4 (1Gb iSCSI, OPT)
RER10G0HIO2 (10Gb iSCSI RJ-45, OPT)
RES10G0HIO2 (10Gb iSCSI SFP+, OPT)
RSS06G0HIO2 (6Gb SAS, OPT)

Host board

System/drawer FAN Module

Power supply module

MUX board

Fibre SFP

RS-232 Cable

Cable

Rackmount Kits*5

Cache Momery*3

BBU or CBM*4

CD, Manual & Quick 
Installation Guide*6 

Embedded in PSU
9474FAN (drawer fan, INC x 3)

9474LOCKERV (INC x 48)

9370CSFP8G (8Gb FC, OPT)
9370CSFP16G (16Gb FC, OPT)
9370CSFP10G (10Gb ISCS SFP+, OPT)

9373AYCAB (INCx1)

9373ASCAB (OPT)

9270CFCCab04 (1M FC cable, OPT)
9270CFCCab05 (5M FC cable, OPT)
9270CFCCab06 (10M FC cable, OPT)
9270CmSASCab7 (0.5M SAS cable, OPT)
9270CmSASCab6 (1.7M SAS cable, OPT)
9270CmSASCab8 (1.2M SAS cable, OPT)
9270CmSASCab9 (2.6M SAS cable, OPT)

4 x 8Gb FC ports
2 x 16Gb FC ports
4 x 1Gb iSCSI ports
2 x 10Gb iSCSI ports (SFP+ or RJ-45)
2 x 6Gb SAS ports

2 x 1600W

84SC30RI60MB (w/2GB)
84SC30RI60MC (w/2 x 2GB)
84SC30RI60MD (w/2 x 4GB)
84SC30RI60MF (w/2 x 8GB)

84SC30GI60MB (w/2GB)
84SC30GI60MC (w/2 x 2GB)
84SC30GI60MD (w/2 x 4GB)
84SC30GI60MF (w/2 x 8GB)

RFC08G0HIO4 (8Gb FC, OPT)
RFC16G0HIO2 (16Gb FC, OPT)
RER01G0HIO4 (1Gb iSCSI, OPT)
RER10G0HIO2 (10Gb iSCSI RJ-45, OPT)
RES10G0HIO2 (10Gb iSCSI SFP+, OPT)
RSS06G0HIO2 (6Gb SAS, OPT)

9370CSFP8G (8Gb FC, OPT)
9370CSFP16G (16Gb FC, OPT)
9370CSFP10G (10Gb ISCS SFP+, OPT)

9373AYCAB (INCx1)

9373ASCAB (OPT)

9270CFCCab04 (1M FC cable, OPT)
9270CFCCab05 (5M FC cable, OPT)
9270CFCCab06 (10M FC cable, OPT)
9270CmSASCab7 (0.5M SAS cable, OPT)
9270CmSASCab6 (1.7M SAS cable, OPT)
9270CmSASCab8 (1.2M SAS cable, OPT)
9270CmSASCab9 (2.6M SAS cable, OPT)

9474CSlider36 (INCx1)

DDR3NNCMB2 (2GB DDR-III)
DDR3NNCMC4 (4GB DDR-III)
DDR3NNCMD (8GB DDR-III)

DDR3NNCMB2 (2GB DDR-III)
DDR3NNCMC4 (4GB DDR-III)
DDR3NNCMD (8GB DDR-III)

9383CCBM (INCx2)
9383CBBU (OPT)

QIG (INC x 1)
CD (INC x 2)

1. Host-side dual-loop is supported by using multi-path software on  the OS or EonPath to provide path redundancy. Drive-side dual-loop is supported by RAID controllers with Fibre Channel drive side connecting. 

        RAID controller provides redundant path and dynamic load balancing across dual-loops. 
* 2. SAS expansion ports connect SAS JBOD when there is a need to expand subsystem capacity. 
* 3.  We do not recommend using 3rd-party memory module due to compatibility issues. Please contact Infortrend for compatible memory modules. 
* 4. There two cache backup methods. One is battery backup, providing  power to cache memory during power outages. Another is cache backup module, providing power to save cache memory data into a flash 
        module during power outages. A cache backup module(CBM)consists of a BBU and Flash module. 
* 5. For details about rackmount kits, please refer to page 15. 
* 6. All hardware and software manuals are provided in PDF format in the product CD and SANWatch CD. The Quick Installation Guide (QIG) provides basic steps to set up and configure the subsystem and activate 
        the software licenses.  For detailed functions and settings, please refer to the hardware and software manual. 

2

9475FANMOD (INC x 3)

9475CPSU (INC x 2)

9474LOCKERV (INC x 60)

Drive tray/drive locker

9474PSU (INC x 3)

8

High IOPS Solutions

Summary of Contents for EonStor DS 3000 Series

Page 1: ...EonStor DS 3000 Series Product Quick Reference Guide...

Page 2: ...s EonNAS Pro and EonNAS 1000 Series Benchmark Reviews awards their Golden Tachometer Award to Infortrend EonNAS 1100 Infortrend sign a distribution agreement with Russia s Merlion Infortrend EonStor D...

Page 3: ...ortrend Technology Inc All rights reserved Any information provided herein is without warranties of any kind of and is subject to change without prior notice Infortrend EonStor SANWatch and EonPath ar...

Page 4: ...le as needed via expansion enclosures Intuitive SANWatch 3 0 UI offers detailed yet easy to learn storage supervision Clearly understandable event and error messages enhance management maintenance and...

Page 5: ...SU INC x 2 9373CDTray INC x 12 9373CDHTray OPT 9373CMUX3G OPT 9370CSFP8G 8Gb FC OPT 9370CSFP16G 16Gb FC OPT 9370CSFP10G 10Gb ISCS SFP OPT 9373AYCAB INCx1 9373ASCAB OPT 9270CFCCab04 1M FC cable OPT 927...

Page 6: ...C x 16 9373CDHTray OPT 9373CMUX3G OPT 9370CSFP8G 8Gb FC OPT 9370CSFP16G 16Gb FC OPT 9370CSFP10G 10Gb ISCS SFP OPT 9373AYCAB INCx1 9373ASCAB OPT 9270CFCCab04 1M FC cable OPT 9270CFCCab05 5M FC cable OP...

Page 7: ...x 3 9370CSFP8G 8Gb FC OPT 9370CSFP16G 16Gb FC OPT 9370CSFP10G 10Gb ISCS SFP OPT 9373AYCAB INC x 1 9373ASCAB OPT 9270CFCCab04 1M FC cable OPT 9270CFCCab05 5M FC cable OPT 9270CFCCab06 10M FC cable OPT...

Page 8: ...n PSU 9373CPSU INCx2 9373CDTray INC x 12 9373CDHTray OPT 9373CMUX3G OPT 9370CSFP8G 8Gb FC OPT 9370CSFP16G 16Gb FC OPT 9370CSFP10G 10Gb ISCS SFP OPT 9373AYCAB INC x 1 9373ASCAB OPT 9270CFCCab04 1M FC c...

Page 9: ...in PSU 9373CPSU INC x 2 9373CDTray INC x 16 9373CDHTray OPT 9373CMUX3G OPT 9370CSFP8G 8Gb FC OPT 9370CSFP16G 16Gb FC OPT 9370CSFP10G 10Gb ISCS SFP OPT 9373AYCAB INC x 1 9270CFCCab04 1M FC cable OPT 92...

Page 10: ...9474FAN drawer fan INC x 3 9474LOCKERV INC x 48 9370CSFP8G 8Gb FC OPT 9370CSFP16G 16Gb FC OPT 9370CSFP10G 10Gb ISCS SFP OPT 9373AYCAB INCx1 9373ASCAB OPT 9270CFCCab04 1M FC cable OPT 9270CFCCab05 5M...

Page 11: ...270CmSASCab6 1 7M SAS cable OPT 9270CmSASCab8 1 2M SAS cable OPT 9270CmSASCab9 2 6M SAS cable OPT Model Form factor Controller Host channel1 per ctrl Drive channel1 per ctrl Hot swap cooling modules H...

Page 12: ...3016GTE 3U RAID ESDS 3024R ESDS 3024RT ESDS 3024G ESDS 3024GT ESDS 3048RE ESDS 3048RTE ESDS 3048GE ESDS 3048GTE ESDS 3060RE ESDS 3060RTE ESDS 3060GE ESDS 3060GTE 4U RAID 312 312 316 316 324 324 336 3...

Page 13: ...OUT SAS IN Link Link SAS OUT SAS IN Link Link SAS OUT SAS IN Link Link SAS OUT SAS IN Link Link SAS OUT SAS IN Link Link SAS OUT SAS IN Link Link 1st JBOD 2nd JBOD Last JBOD 1st JBOD 2nd JBOD Last JBO...

Page 14: ...ect with expansion RAID System RAID System 1st JBOD 2nd JBOD Last JBOD 1st JBOD 2nd JBOD Last JBOD 4U 48bay LFF subsystems Dual controller Single controller Refer to expansion guide for the maximum nu...

Page 15: ...ting the maximum numbers of expansion enclosures Refer to expansion guide for the maximum numbers of expansion enclosures Dual redundant controller subsystems can connect with expansion enclosures by...

Page 16: ...10Gb iSCSI RJ45 10Gb iSCSI SFP 16Gb Fibre Host board options JBOD Link 1 JBOD Link 2 JBOD Link 1 JBOD Link 1 JBOD Link 2 JBOD Link 1 JBOD 1 Link JBOD 2 Link 0 1 JBOD 1 Link 0 1 With FC iSCSI and SAS...

Page 17: ...e to pole 1 Maximum Length Pole to pole 1 609 6 mm 24 inches 914 4 mm 36 inches 762 mm 30 inches 939 8 mm 37 inches 1 The pole to pole length or post to post length refers to the distance between the...

Page 18: ...DS 3024RT ESDS 3024G ESDS 3024GT 43 36kg 95 59lbs 67 36kg 148 50lbs 496 5mm 19 57 568 80mm 22 40 25 7kg 56 66lbs 646mm 25 43 787mm 30 98 605mm 23 81 174mm 6 85 445mm 17 52 41 52kg 91 54lbs 65 52kg 144...

Page 19: ...in time differential copies without disrupting online applications Restore deleted files or roll data volume back in seconds based on space saving recovery points reate independent point in time and...

Page 20: ...of their respective owners Asia Pacific Taipei Taiwan Infortrend Technology Inc Tel 886 2 2226 0126 E mail sales ap infortrend com Americas Sunnyvale USA Infortrend Corporation Tel 1 408 988 5088 E ma...

Page 21: ...Click below to find more Mipaper at www lcis com tw Mipaper at www lcis com tw...

Reviews: