Infopia GlucoLab Instructions For Use Manual Download Page 3

4

Dear System 

Owner

Thank you for choosing the

Blood Glucose Monitoring

System.

This instructions for use contains everything you need to know about
your new Blood Glucose Monitoring System and how it works.
Please take a moment to read it carefully, before using your new
system.

In choosing the

Blood Glucose Monitoring System, you

have selected one of the most convenient, easy to use and less
painful systems available. It gives you accurate results in just 5
seconds using only 1

blood sample from Forearm, Upper arm,

Palm, Fingertips, Thigh, as well as Calf. You will find that testing on
your arm or leg is less painful than testing on your fingertips, since
they have fewer nerve endings. What’s more, the 

stores

up to 250 blood glucose test results and can identify up to 100
different users (see ID function).

Checking your blood glucose levels on a regular basis can make a
big difference in how well you manage your diabetes. Our goal is to
help you make it as comfortable and convenient as possible. 

Before you get started, it is important to complete the warranty
registration card included in your kit, and mail it back to Obelis S.A.
Doing this will help us serve your needs better.

Intended Purpose

The                  Blood Glucose Monitoring System is intended for use
outside the body only (in vitro diagnostic use) and self-testing. The
recorded results make it easier for your doctor to access your
metabolic control. However, the self-testing should not take the place
of overall diabetes management assessment from your doctor. It
should be used only for testing blood glucose(sugar) and only with
fresh capillary whole blood samples. The                  Blood Glucose
Monitoring System is intended for use in the home and in
professional setting to monitor blood glucose levels.

Test Principle

Glucose in the blood sample will react to the electrodes in the test strip,
generating an electrical current that will stimulate a chemical action.
This reaction is measured by the                  meter and displayed as
your blood glucose result. The                   Blood Glucose Monitoring
System is plasma-calibrated to allow easy comparison of results with
laboratory methods.

5

Caution : 

If the code on the LCD window and on the blood glucose

test vial does not match, follow the coding procedure for accurate
results.

Summary of Contents for GlucoLab

Page 1: ...59 54 Fax 32 2 732 60 03 E Mail mail obelis net INFM08A IMC00099 Rev 2014 06 02 Lancet infopia Co Ltd Lancing Device GMMC Rm 1112 Ace Tower 9th Bldg 130 Digital ro Geumcheon gu Seoul Korea Instruction...

Page 2: ...Blood Glucose Monitoring System for self testing Quick and Smart Blood Glucose Monitoring System for self testing...

Page 3: ...is important to complete the warranty registration card included in your kit and mail it back to Obelis S A Doing this will help us serve your needs better Intended Purpose The Blood Glucose Monitorin...

Page 4: ...b Meter 34 Changing Your Battery 35 Disposal of meter and batteries 36 Trouble Shooting 37 40 Specifications 41 Warranty 42 Symbol Reference 43 7 6 Caution Before using any product please read all ins...

Page 5: ...attery Carrying case Your Blood Glucose Monitoring System has been sealed and it should contain all of the parts shown above Please return the system to place of purchase or contact your nearest repre...

Page 6: ...only DO NOT RE USE 8 Keep the blood glucose test strip vial away from children 9 Pleaserefertotheuser smanualfor bloodglucoseteststripforadditionalinformation 10 Discard the used blood glucose test s...

Page 7: ...Do not reuse Dehydration may lower test results If you are severely dehydrated contact you physician immediately Inaccurate results may occur when in shock hypotensive hyperglycemic or hyperosmolar st...

Page 8: ...eTemperatureUnit Settingtestingaverages Setting the Alarm After pressing and releasing either or buttons to set or enter After pressing and releasing either or buttons to set the average of testing da...

Page 9: ...ut be careful not to bend The code number should appear in the LCD window for 3 seconds example C18 Compare the code number on the meter s LCD window with the code number on the test strip vial If the...

Page 10: ...a convenient medical tool for collecting capillary blood samples for glucose monitoring or other tests which require one or two drops of blood As a more advanced lancing device it provides ultimate sa...

Page 11: ...port and re start the procedure from the beginning If the code on the LCD display window and on the test vial do not match follow the coding procedure for accurate results refer p18 If you apply your...

Page 12: ...he Hi Lo message will be shown on the LCD refer p39 Safely discard used blood glucose test strips and lancets Test Strip Insertion Completely filled Poorly filled Applying Blood Step 2 Place your fing...

Page 13: ...with your result then press Record the result value in your logbook When glucose test strip is removed glucose test meter turns off automatically CAUTION Although you already set the user option and i...

Page 14: ...ontrol solution should be used Whenever you suspect the blood glucose test meter or blood glucose test strip is not functioning properly If your blood glucose test results are not consistent with your...

Page 15: ...0 test results in its built in memory and records the average glucose level for the number of days which you had preset to be calculated and saved These values can be recalled in the LCD display at an...

Page 16: ...physical exercise or whenever you feel that your glucose levels may be changing rapidly should be done from the fingertip You should also use fingertip testing whenever you have a concern about hypog...

Page 17: ...into the channel of the blood glucose test strip You may get an inaccurate result if the blood sample is not completely filled in a single action To bring fresh blood to the surface of the test site r...

Page 18: ...he outside of the blood glucose test meter Your blood glucose test meter is a precision instrument Please handle it with care Lancet Device Clean the lancet device and caps with soap and tepid water T...

Page 19: ...and Council Directive 2012 19 EU aimed to reducing the amount of EEE waste going for final disposal The manufacturer has specific instructions for the recovery of the meter Please contact your distri...

Page 20: ...l result re test with blood sample two or three times When Lo message persists please consult a doctor for assistance Check the accuracy of your test strip by perfoming a control solution test With no...

Page 21: ...Shooting MESSAGE Problem Action Required The meter does not Battery is dead or there is a Change the battery and if power on problem with the meter the problem persists contact your local representat...

Page 22: ...acturer Authorized representative in the European Community Biohazard Waste batteries and accumulators 42 43 Warranty Five Year Warranty The meter has a full five year warranty from the original date...

Page 23: ...Memo 44 INFM08A IMC00099 Rev 2014 06 02...

Reviews: