background image

Summary of Contents for Element Lite

Page 1: ......

Page 2: ......

Page 3: ...and proper use of the glucometer Please pay close attention when handling blood Improper procedures may cause serious hazards to your health The Element Lite Blood Glucose Monitoring System contains...

Page 4: ...ries 10 Troubleshooting 11 Specifications 12 Conversion table mmol L mg dL 13 Warranty 14 Symbol reference 7 8 9 10 11 12 13 14 15 16 17 18 19 21 22 24 25 26 27 28 29 30 31 32 33 34 35 35 36 38 39 40...

Page 5: ...meter in a dry environment especially if synthetic materials are present Synthetic clothes carpets etc may cause damaging static discharges in a dry environment 2 Do not use Element Lite blood glucos...

Page 6: ...scard remaining Element Lite blood glucose test strips 6 months after first opening the vial 4 Close the vial cap tightly immediately after removing a Element Lite blood glucose test strip 5 Do not us...

Page 7: ...curately high results Lipemic samples Cholesterol up to 500 mg dL or triglyceride up to 3000 mg dL do not significantly affect the results Glucose values however in specimens beyond these levels shoul...

Page 8: ...test results are displayed correctly after re setting the test unit See also conversion table on page 40 2 Without setting the date properly the average glucose level and the results in memory will no...

Page 9: ...n range is not the recommended range for your blood glucose level For example If you use a normal glucose control solution you must use the normal range printed on the side of the blood glucose test s...

Page 10: ...capillary blood samples for glucose monitoring or other tests which require one or two drops of blood As a more advanced lancing device it provides ultimate safety and comfort for obtaining blood sam...

Page 11: ...Ultra Fine Cleanlet Fine E Z Ject G P Lite Microlet Monolet One Touch Soft Touch Therasense Ultra TLC and Unilet GP Note Some less known lancets may not work properly with the due to their dimensions...

Page 12: ...screen indicat ing the blood glucose test meter is ready for testing Note Inserting the test strip in the wrong direction will turn the meter on but you will be unable to test Testing Procedure 23 CA...

Page 13: ...ing set up press and button to select the activity that correlates with your result refer to p10 then press If you did not select to use user activity option during set up press to continue to step 4...

Page 14: ...ucose test strip and lancet accordingly Test Strip Ejector Function 27 The Element Lite blood glucose test meter stores up to 365 test results in its built in memory along with the average sugar level...

Page 15: ...tion Only selected individual test results are deleted when you recalled test results in the user ID condition The deleted test results can t be recovered Please be careful in deleting the test result...

Page 16: ...henever you feel that your glucose levels may be changing rapidly should be done from the fingertip You should also use fingertip testing whenever you have a concern about hypoglyce mia insulin reacti...

Page 17: ...straight up be careful not to smear the blood on your testing site 5 Place the edge of the blood glucose test strip to the drop of blood 6 The blood will automatically draw into the channel of the bl...

Page 18: ...g device lancets or blood glucose test strips contact your local representative 7 Discard the used lancets carefully to prevent any infection Cleaning Your Meter and Maintenance 35 The low battery ico...

Page 19: ...n Required 37 Please wait for the LCD to display icon blinking before applying your blood sample User applied the blood sample before the LCD display was blinking Problem with the Auto coding label Th...

Page 20: ...nje te av Troubleshooting Message Problem Action Required The test result is higher than 600mg dL Check the accuracy of your blood glucose test strip by performing a glucose control solution test If t...

Page 21: ...41 Three Year Warranty If at any time during the first three years after purchase the blood glucose test meter does not work for any reason with the exception of obvious abuse misuse or disastrous da...

Page 22: ...consult accompanying documents In Vitro Diagnostics Medical Device Batch code Catalogue Number Temperature limitation Serial number Date of Manufacture Manufacturer Keep away from sunlight For Self t...

Reviews: