Page 1: ...Wireless Smart Gluco Monitoring System OWNER S MANUAL...

Page 2: ...CIPLE IMPORTANT TEST INFORMATION FIRST TIME SETUP INSTRUCTIONS DATA SYNCING REVIEWING SAVED TEST RESULTS ON THE METER CLEANING AND DISINFECTION SIGNS OF POTENTIAL PHYSICAL AND PERFORMANCE DETERIORATIO...

Page 3: ...ART GLUCO MONITORING SYSTEM SPECIFICATIONS MAINTENANCE AND STORAGE OF YOUR IHEALTH SYSTEM LIMITATIONS OF USE SYSTEM TROUBLESHOOTING DISPLAY MESSAGES TROUBLESHOOTING INTERNATIONAL BLOOD GLUCOSE MEASURE...

Page 4: ...body in vitro diagnostic use by people with diabetes at home as an aid to monitor the effectiveness of diabetes control The iHealth system should not be used for the diagnosis of or screening for dia...

Page 5: ...re considered biohazards and can potentially transmit infectious diseases even after you have performed cleaning and disinfection Please refer to the resources identified below for detailed informatio...

Page 6: ...test strip BLUETOOTH SYMBOL Appears when the meter is connected with iOS device through Bluetooth function TEST RESULT DISPLAY Displays test result MEASUREMENT UNIT Appears with the test result either...

Page 7: ...t iHealth Control Solution iHealth Test Strip Absorbent hole Confirmation window Test strip handle Contact bars Lancet cover Control Solution Mobile Device Compatibility 4 Head Main body Release butto...

Page 8: ...Inaccurate results may occur in severely hypotensive individuals or patients who are in shock Test results that are lower than actual values may occur in individuals who are in a hyperglycemic hypero...

Page 9: ...hare or re use lancets Please refer to the Lancing Device Manual for the detailed procedure For more detailed information please refer to the resources identified below FDA Public Health Notification...

Page 10: ...used your meter for some time appears for three seconds when the battery in your meter is low on power You must recharge the battery before using it again After three seconds the meter shuts off auto...

Page 11: ...you are on Android devices Select the model name BG5xxxxxx in the Bluetooth menu to pair and connect 4 Launch the app to connect the meter to the app The Bluetooth symbol will flash and remain lighte...

Page 12: ...QR code ONLY when a new vial is opened for the first time NOTE You can skip step 1 2 to take readings without connecting the meter to the app if the meter has been synced refer to Sync the meter secti...

Page 13: ...ed Press the release button to puncture the site Gently squeeze your finger until a drop of blood forms Wipe away the first blood drop and squeeze until a second small blood drops forms 6 Apply the bl...

Page 14: ...n the meter display or when you hear a sound alert from your mobile device 7 Read the test results If the meter is not connected to the app the test result will appear on the meter after counting down...

Page 15: ...ost recent blood glucose test results When the meter needs to save a new test result and has already stored 500 test results the oldest test result will be overwritten by the new test result When the...

Page 16: ...hyl benzyl ammonium chloride as the active ingredient have been shown to be safe for use with the meter and lancing device You can purchase this product from the suppliers listed below 1 Visit the web...

Page 17: ...cting towelette Do not insert the disinfecting towelette into the test strip port or else the performance of the meter may be affected If you encounter one of the following circumstances stop using th...

Page 18: ...results to fingertip testing when used at appropriate times 15 Upper Arm Forearm Palm Finger Calf Thigh 1 The device does not work for example the iOS device can t begin testing when the meter is conn...

Page 19: ...evels are not changing rapidly Alternate Site Testing is suitable in the following instances In a pre meal or fasting state two hours or more after the last meal Two hours or more after taking insulin...

Page 20: ...symbol appears on the meter display press the memory button to turn on the CTL mode When the CTL symbol appears the meter is in control solution test mode and will not save this test result in memory...

Page 21: ...e the absorbent hole of the test strip to catch the drop Once the confirmation window fills completely the meter will start counting down Remove the control solution sample from the test strip when th...

Page 22: ...y not be working properly Discontinue use and call iHealth Labs Customer Service at 1 855 816 7705 for assistance To purchase additional control solution call iHealth Labs Customer Service NOTE Do not...

Page 23: ...re taken and tested within 15 minutes of each other Wash your hands before obtaining a blood sample Never use your glucose meter with blood samples collected in a test tube Use fresh capillary blood o...

Page 24: ...micro liter 12 Life span Five years 13 The table of substances below shows the highest concentration without significant interference 10 error Compounds Ascorbic acid Uric acid Acetaminophen Bilirubin...

Page 25: ...mples icterus samples or high lipemia samples Patients undergoing oxygen therapy may yield falsely lower results Not for use for patients in a hyperglycemic hyperosmolar state with or without ketosis...

Page 26: ...st using a new test strip If your result still flashes Lo seek medical advice immediately Blood glucose level is higher than 600 mg dL 33 3mmol L Wash and dry your hands and the test site thoroughly R...

Page 27: ...eter is not synced to the app on your iOS device yet The remaining test strip in the vial is 0 Follow the instructions above in the FIRST TIME SETUP INSTRUCTIONS to sync your meter Scan a new vial of...

Page 28: ...e sample cannot be applied or the speed of application is too slow 4 iHealth system is not performing due to the environment being above or below room temperature 4 Bring the iHealth system to a room...

Page 29: ...mg dL mg dL mg dL mg dL mg dL mg dL mg dL mg dL mg dL mg dL mg dL mg dL mg dL Argentina Austria Bahrain Bangladesh Belgium Brazil Caribbean Countries Chile Colombia Ecuador Egypt France Georgia Greece...

Page 30: ...use for a period of three years from the date of purchase by the original purchaser Warranty Period Under this Limited Warranty if a defect arises and a mg dL mg dL mg dL mg dL mg dL mg dL mg dL mg d...

Page 31: ...ively and has been certified by the developer to meet Apple performance standards Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards Pleas...

Page 32: ...ste should not be disposed of with household waste Please recycle where facilities exist Check with your local authority or retailer for recycling advice Keep dry Bluetooth sign Serial number FCC ID T...

Page 33: ...n accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interfer ence will not occur in a particular installation If this product d...

Page 34: ...pment This product complies with Industry Canada IC RSS 210 This product is approved in accordance to R TTE directive transmitter IC NOTICE This device complies with Industry Canada licence exempt RSS...