INSIGHT DLP
DIRECTOR 2200 Appliance Hardware Installation Guide
www.infolocktech.com
7. REAR PANEL CONNECTIONS
(continued)
Step 1
Connect the Ethernet cables for MGMT, DLP, and SPAN
(if required).
Step 2
Connect any other required cables.
Step 3
Connect the power cords.
Step 4
Proceed to
Section 8, Front Panel Operation
on page 9.
POWER SUPPLY STATUS LED
There is a single bi-color Power Good LED on each power supply
module to indicate power supply status. The LED operation is
defined in the table below.
NOTE:
The server offers redundant, hot-swap capability. The
connections to AC mains should be made in a manner appropriate
to local code and consistent with customer power distribution with
or without redundant sources.
CAUTION
The power supply is hot-swappable only when you have a server
with redundant power supplies installed. If you only have one
power supply installed, before removing or replacing the power
supply, you must first take the server out of service, turn off all
peripheral devices connected to the server, turn off the server by
pressing the power button, and unplug the AC power cord from the
server or wall outlet.
POWER SUPPLY CONDITION
Output ON and OK
No AC power to both power supplies
AC present / only 12 VSB on (PS off) or PS in cold
redundant state
AC cord unplugged or AC power lost; with a
second power supply in parallel still with AC input power
Power supply warning events where the power supply
continues to operate; high temp, high power, high
current, slow fan
Power supply critical event causing a shutdown; failure,
OCP, OVP, fan fail
Power supply FW updating
LED STATE
GREEN
OFF
1Hz Blinking
GREEN
AMBER
1Hz Blinking
AMBER
AMBER
2Hz Blinking
GREEN
In normal operation the Power Good LED on Power Supply Module 1 will be SOLID
GREEN and the LED on Power Supply Module 2 will BLINK GREEN (redundant
standby), if the system is powered down both LEDs will BLINK GREEN.