
INF-MOTWALL / XSD1U
Installation Instructions
12
Site Requirements (Steel Studs without Plywood Backing)
Figure 13
(Must be centered over two studs)
Drywall
**1/2" minimum
Drywall Thickness
INF-MOTWALL / XSD1U Installation Location
FRONT
(Both Sides of Stud)
There must be a minimum of
1-7/8" (48mm) clearance
inside wall
16" (on center) Studs
If back side of wall is unfinished, drywall must be installed
to a minimum of one stud left and right of the studs
being used to install the mount. Drywall must be
secured to studs with screws 12" on center
Steel Stud (2 x 4 / 25ga minimum)
Stud type and structural strength must conform to the North American
Specification for the Design of Cold-Formed Steel Structural Members.
**See hazard statement
on page 2!
[362, 125 18, C-Shape, S - Stud Section]