5. Operation Controls and Functions
Number
Name
5.1 Transmitter Panel
Function description
1
2
3
4
5
6
7
8
1
HDMI In
Connect with HDMI source
.
2
IR In
Work with far-end IR Out port, connect with 12V IR
Receiver to collect IR signal to control far-end display
device from local.
3
IR Out
Work with far-end IR In port, connect with 12V IR
Emitter to send IR signal to control input source device
from remmote.
4
RS232
connector
If one is connected with control device (e.g.PC), and the
other should be connected with the third-party that need
to be controlled.
5
DC 12V
Support bi-directional PoC, one of ports should be
connected with 12V DC 1A power adaptor.
6
Power LED OFF: No power.
Red: DC power present
7
HDBT Out
Connect to the HDBT In socket on Receiver.
8
RS232 Mode
switch
Ctrl — RS232 pass-through control mode.
Update — Update Valens IC program, connect a PC to
the RS232 port, and then double-click the update file
(.bat).