![Infinova V6202-T03 Series Instruction Manual Download Page 50](http://html.mh-extra.com/html/infinova/v6202-t03-series/v6202-t03-series_instruction-manual_2056927050.webp)
46
Figure 4-37 Alarm Settings
Alarm Configuration
I/O In 1, I/O In 2: Settable 2-channel alarm inputs.
Each alarm input has 2 modes: Grounded Circuit or Open Circuit.
Alarmout Contact: used to set sending way of alarm.
Local Contact: I/O out is triggered by I/O alarm in, motion detection alarm,
shelter alarm, SD card out, network link down or IP address conflict. Default:
Local Contact.
Net Contact: I/O out is controlled by the surveillance management software.
Note:
This function needs to be supported by digital video surveillance
management software like V2216. If Net Contact is selected, users have to set
Alarm Server IP the same as the IP address of V2216-CMS server. After