30
Item
Function
I
TE
Transmission Enabled.
Options
z
Y
= yes (to enable alarm signals to transmit to a remote site).
When Y, enter the remote site number in the entry next to it.
z
N
= no (to disable alarm signals to transmit to a remote site. The default is "N").
z
Enter the transmission SN before Y/N, and enter the site number after Y/N.
Item
Function
J
RACN
Used to indicate which alarm the matrix takes this alarm as to deal with after the local alarm
transmits to the remote matrix.
1)
Enter the alarm site number;
2)
Press the ACK key to select.
5.3.6 Monitor Status
SYSTEM
1 SET TIME AND DATE
2 SET SYSTEM TOURS
3 SET SYSTEM SALVOS
4 SET EVENT TIMERS
5 SET ALARM CONTACTS
6 MONITOR STATUS
7 SET RELAY
RETURN MAIN
MONITOR STATUS
ACK TO EXIT
MON
01
02
03
04
05
06
07
08
CAM
0015
0021
0032
0005
0009
0002
0014
0001
TOUR
01
02
03
04
05
--
--
--
STS
R
H
A
R
H
R
R
H
SITE
Select the MONITOR STATUS from the SYSTEM menu to access
the Monitor Status menu. A single menu screen displays status
information for 8 cameras. The CLOSE/OPEN keys can be used for
page-down/page-up.
The menu screen displays the following information of monitors:
MONITOR STATUS
MON
01
CAM
0015
STS
R
TOUR
01
A
B
C
D
E
SITE
Item
Function
A
MON
Refers to the monitor in the system.
B
SITE
Indicates the remote site number currently being controlled.
C
CAM
Indicates the camera that is currently displayed on the monitor.
D
STS
Displays the monitor status, i.e.,
z
H (Hold);
z
R (Run);
z
A (Alarmed);
z
S (Salvo).
E
TOUR
Indicates the tour that is currently running on the monitor.
Sample Menu
MONITOR STATUS
MON
01
02
CAM
0015
0021
STS
R
H
TOUR
01
02
SITE
The sample menu indicates that:
z
Monitor 1 is displaying Camera 15, and is in a Run status in Tour 01.
z
Monitor 2 is displaying Camera 21, and is in a Hold status in Tour 02.
5.3.7 Set Relay
SYSTEM
1 SET TIME AND DATE
2 SET SYSTEM TOURS
3 SET SYSTEM SALVOS
4 SET EVENT TIMERS
5 SET ALARM CONTACTS
6 MONITOR STATUS
7 SET RELAY
RETURN MAIN
SET RELAY
PREVIOUS MENU
MON
001
002
003
004
005
006
007
008
RELAY 1
N
N
N
N
N
N
N
N
RELAY 2
N
N
N
N
N
N
N
N
The SET RELAY menu (shown left) is used to assign the V2015A
two built-in relay outputs to follow two armed monitors
respectively. Once the associated monitor is alarmed, the
corresponding relay will be activated to control such alarm-related
devices as DVRs or alarm bells upon alarm.
A single screen page permits setup relays for 8 monitors. The
CLOSE/OPEN keys can be used for page-down/page-up.