Parameter
Specification
Unit
QA Test
Limits
Conditions
Notes
Line In (L,R) & LFE
YES
--
functional
Dual RCA jack, Lor R is used in LFE mode
Spkr/Hi Level In
YES
--
functional
Binding post connector L&R
Signal Sensing (ATO)
Auto-Turn-On (yes/no)
YES
functional Auto - on selection switch in Auto
ATO Input test frequency
50
Hz
functional
"
ATO Level LFE Input
2
mV
functional
"
ATO Level Speaker in
50
mV
functional
"
ATO Turn-on time
2 seconds
functional
Amp connected and AC on, then
input signal applied
Auto Mute/ Turn-OFF Time
15
minutes
17
(T) Time before muting, after input
signal is removed
Auto turn of time (T) must be 10 > T < 17 Minut
Power on Delay time
3
sec.
4
AC Power Applied
Transients/Pops
ATO Transient
5 mV-peak
n/a
@ Speaker Outputs
Turn-on Transient
50 mV-peak
1V-pk-pk @ Speaker Outputs
AC Line cycled from OFF to ON
Turn-off Transient
50 mV-peak
1V-pk-pk @ Speaker Outputs
AC Line cycled from ON to OFF
Efficiency
Efficiency
70
%
65
Rated power
Nominal Line voltage 120 VAC
Stand-by Input Power
10
10
@ nominal line voltage, Amp in
OFF state, RED LED activated
Maximum allowable input power LED in RED,
Class D inactive
Stand-by Input Power
12
Watts
15
@ nom. line voltage, Amp in On
state, Green LED activated
Maximum allowable input power under nominal
Input voltage and frequency, in stand-by mode
(HOT or COLD operation, LED GREEN). Class
D active but no signal applied.
Power Cons. @ rated power
325
Watts
338
@ nom. line voltage
220 Watts @ 6.0 Ohms nominal line voltage
Protection
Short Circuit Protection
YES
functional Direct short at output
Amplifier should resume operation after short
circuit condition removal
Thermal Protection
YES
functional @1/8 max unclipped Power
Temperature rise in accessible metal parts
should not exceed 35K rise for domestic version
or 30K rise for European versions (refer to
requirements sheet). Unit is protected for over-
temperature conditions
DC Offset Protection
YES
-
DC present at Speaker Out leads
Relay opens duisng a DC output condition
Line Fuse Rating
USA-Domestic
4
Amps
Type-T or Slo Blo-250 V
EU
2
Amps
Type-T or Slo Blo-250 V
Internal fuse with UL/SEMKO rated holder
SW-12
3
Summary of Contents for Beta SW-12
Page 10: ...SW 12 9 ...
Page 21: ...SW 12 20 ...
Page 22: ...SW 12 21 ...
Page 23: ...SW 12 22 ...
Page 24: ...SW 12 23 ...
Page 25: ...SW 12 24 ...
Page 26: ...SW 12 25 ...
Page 27: ...SW 12 26 ...
Page 28: ...SW 12 27 ...
Page 29: ...SW 12 28 ...
Page 30: ...29 SW 12 ...
Page 31: ...85 85 01 New DESIGN SW 12 30 ...
Page 32: ...01 New DESIGN SW 12 31 ...
Page 33: ...01 New DESIGN SW 12 32 ...
Page 34: ...01 New DESIGN SW 12 33 ...
Page 35: ...105 105 01 02 New DESIGN CHANGE R14 F1 C1 C4 SW 12 34 ...
Page 36: ...01 02 New DESIGN CHANGE R14 F1 C1 C4 SW 12 35 ...
Page 37: ...01 02 New DESIGN CHANGE R14 F1 C1 C4 SW 12 36 ...
Page 38: ...01 02 New DESIGN CHANGE R14 F1 C1 C4 SW 12 37 ...