890 HD BF INSTALLATION INSTRUCTIONS
The battery manual override option is a back-up supply in case of a power failure / power cut to the
property. The battery holder and adaptor lead are provided within the packing of the appliance. (Please
note that the “C” cell batteries are not included). It is goo
d practice to demonstrate the battery option to
the customer during the commissioning process.
The firebox assembly can be retained using the following two methods.
Flue connection
Once the fire is fixing in position pass a tape measure through the core-drilled hole and record the distance
from the back of the fire to the outside wall. Cut the outer tube to the recorded length. Add
18mm
to this
measurement to determine the length of the inner tube and cut to size.
NOTE: The inner tube will be 18mm longer than the outer tube
Using flue seal or fire cement apply a small bead to internal ends of both the inner and outer pipes to
ensure an airtight seal is made when the flue is positioned onto the fire. Position the flue onto the fire
ensuring they are fully mated and wall mounting brackets are in contact with the wall face. Secure the flue
terminal to the outer wall using 4 off fixings. It is recommended to seal around the flue terminal to prevent
the ingress of water and to reduce the chance of a draft.
If the flue outlet is fitted below 2m from the floor or a balcony then the flue terminal guard must be fitted.
Summary of Contents for 890 HDBF
Page 35: ...P a g e 34 Issue No 2 890 HD BF SERVICE FAULT FINDING INSTRUCTIONS...
Page 36: ...P a g e 35 Issue No 2 890 HD BF SERVICE FAULT FINDING INSTRUCTIONS Maintenance...
Page 37: ...P a g e 36 Issue No 2 890 HD BF SERVICE FAULT FINDING INSTRUCTIONS...
Page 38: ...P a g e 37 Issue No 2 890 HD BF SERVICE FAULT FINDING INSTRUCTIONS...
Page 46: ...P a g e 45 Issue No 2...
Page 47: ...P a g e 46 Issue No 2...