![Infinity 780HD Instruction For Users Download Page 42](http://html1.mh-extra.com/html/infinity/780hd/780hd_instruction-for-users_2056244042.webp)
P a g e
| 41
LT7185 Issue No 1 (04/17)
780 HD INSTALLATION INSTRUCTIONS
Perform the spillage test at this point before fitting the glass fascia. Refer to the spillage test
procedure on page 45 for guidance on how to perform this test on this appliance.
Now the fire is ready for the glass fascia to be hooked on using the studs on the fascia sliding
them in to place on the slots provided in the side of the fixing frame.
Once fitted make sure that the heat outlet hole in the fascia is at the top to allow for heat
disapation
These studs are on both sides of the fascia these slide in to the slots on the
slide of the fixing bracket