16
17
Display Elements
a “Live” wire indicator
b Wood detection indicator
c Metal detection indicator
d “ZOOM” function indicator
e “ZOOM” measuring indicator
f Measuring indicator
g “AutoCal” calibration indicator
h Indicator for magnetic metals
i Indicator for non-magnetic metals
j Switched-off audio signal indicator
k Battery indication
a
b
c
d
e
f
k
j
i
h
g
TECHNICAL DATA
Maximum scanning depth*:
Ferrous metals
100 mm
Non-ferrous metals (copper)
80 mm
Copper conductors (live)**
50 mm
Wood
20 mm
Automatic switch-off after approx.
5 min
Operating temperature
- 10 °C ... +50 °C
Storage temperature
- 20 °C ... +70 °C
Battery
1 x 9 В 6LR61
Rechargeable battery
1 x 9 В 6F22
Operating lifetime (alkali-manganese
batteries) approx.
6 h
Weight
0,24 kg
* depends on material and size of objects as well as material and condition of
structure
** less scanning depth for wires/conductors that are not “live”
Please observe the article number on the type plate of your measuring tool. The trade
names of the individual measuring tools may vary.
OPERATION
Inserting/Replacing the Battery
Use only alkali-manganese or rechargeable batteries. To open the battery lid
9
, press
the latch
10
in the direction of the arrow and fold up the battery lid. Insert the supplied
battery. Pay attention that the polarity is correct, according to the representation on
the inside of the battery lid.
When the battery indication
k
in the display lights up, measuring is possible for
approx. 1h when using alkali-manganese batteries (service life is shorter with
rechargeable batteries).