Connector Description 

Precision BNC connectors are instrument-grade connectors that operate mode-free up to 10 GHz. They 

feature extremely low VSWR and insertion loss and are designed to non-destructively mate with standard 

BNC connectors.   

 

Connector Care 

Precision connectors must be handled carefully if accurate calibrations and measurements are to be 

obtained. All connectors should be inspected prior to each use. For optimal  measurement results, all 

interfaces should be visually inspected under magnification and cleaned on a regular basis. Proper 

connector contact pin depths should also be verified through regular inspections using a connector gage 

kit to ensure that connectors on both calibration devices and devices under test (DUTs) have contact pin 

depths within recommended tolerances.  
Care should be used whenever aligning connectors. Tighten connector coupling nuts using an appropriate 

torque wrench while holding the opposing connector with an open-end wrench. 
When disconnecting devices, take care not to rock or bend any of the connections. Disconnect devices by 

disengaging the coupling nuts and gently pulling the connectors apart in a straight line. 
Always use protective covers on all connectors when devices are not in use. 
Should a connector become damaged, it should be repaired before it is used again or replaced immediately. 

A damaged connector can damage other mated connectors.

 

 

Summary of Contents for Fairview Microwave FMCK1024

Page 1: ...of Infinite Electronics Inc User Manual BNC Coaxial Calibration Kit DC to 10 GHz Models FMCK1024 Fairview Microwave 301 Leora Ln Suite 100 Lewisville TX 75056 Tel 1 800 715 4396 or 972 649 6678 Fax 9...

Page 2: ...be returned to Fairview Microwave and must be issued a return authorization number by Fairview Microwave prior to shipment Buyer shall prepay shipping charges to Fairview Microwave Obligation is limit...

Page 3: ...nty 2 General Information 4 Calibration Kit Description 4 Maintenance 4 Calibration 4 Supporting Test Port Adapters 4 Electrostatic Discharge Precautions 4 Connector Description 5 Connector Care 5 Con...

Page 4: ...faces is recommended Failure to do so may result in degraded repeatability and accuracy as well as damage to any mated devices Calibration To maintain and certify the calibration kit s ongoing perform...

Page 5: ...oper connector contact pin depths should also be verified through regular inspections using a connector gage kit to ensure that connectors on both calibration devices and devices under test DUTs have...

Page 6: ...d wrench is recommended to hold the body of one device stationary while torquing the nut on the other device or cable This open end wrench is supplied with the calibration kit for this purpose Using t...

Page 7: ...istered trademark of Infinite Electronics Inc 7 Calibration Kit Contents Standard Components SOL FMCK1024 1 ea Short female FMSC3019 1 ea Short male FMSC3020 1 ea Open female FMSC3034 1 ea Open male F...

Page 8: ...ents made by the instrument The calibration standards in this kit have precisely known electrical behavior and during calibration the VNA software uses the raw measurement data and the known behavior...

Page 9: ...2020 Infinite Electronics Inc Fairview Microwave is a registered trademark of Infinite Electronics Inc 9...

Page 10: ...le Calibration Kits Calibration Kits Components keywords calibration ports vna sort y searchtype 1 view_type grid Fairview Microwave Test and Measurement Products https www fairviewmicrowave com nsear...

Page 11: ...ics Inc 11 Contacts Customer Support Sales Fairview Microwave 301 Leora Ln Suite 100 Lewisville TX 75056 USA Phone 800 715 4396 972 649 6678 Fax 972 649 6689 Sales Email sales fairviewmicrowave com Cu...

Reviews: