PLEASE NOTE: The equipment must be directly and permanently mounted on a non-
combustible surface such as concrete and metal. Supports or materials with poor self-
extinguishing requirements must be excluded.

Terminal Blocks

• Line entrance panel with RJ45 connector

• Interconnecting cables used must be UL certified and must be compliant with the CEI 64/8 for video door entry systems:

- UTP CAT 5e for domestic routes dedicated to video door-phone system

- FTP CAT 5e shared routes with tension cables

- UTP CAT 5e for outside with protective sheath in PVC

All cables must be LSZH for Low Smoke Zero Halogen

5

EN

Technical characteristics

• Brushed stainless steel exterior AISI 316 with ABS frame and glass parts are made from ultra-strong, scratch-proof.

• Ready to install semi-surface mounted wall with metal coupling

• The night light is ensured by 4 efficiency LED

• Standby power consumption 7 mA , in conversation : 150mA

• Operating Temperature : -20 

°

to 50 

°

C

• Dust and Water Resistant - Rating IP54

• Mechanical impact resistance level: IK08

• Size : 150 x 175  x2 mm

Maintenance

• Clean the entrance panel using a soft cloth. Do not use any type of chemical product.

Summary of Contents for Small

Page 1: ...Installation and operation manual Z1101 Z1102 Z2101 Z2102 ...

Page 2: ...or to the top edge as shown in the figure Fix the chassis frame to the box using the 2 screws 2 Wire the electronics assembly as shown through the RJ45 connector Position the Small Entrance Panel license tarting from the top and then turning downwards Z1101 Z1102 Small audio video entrance panel for INFINITEPLAY video door entry systems 2 EN 3 Fix the Small Entrance Panel using the 2 screws M3x12 ...

Page 3: ...s dedicated to video door phone system FTP CAT 5e shared routes with tension cables UTP CAT 5e for outside with protective sheath in PVC All cables must be LSZH for Low Smoke Zero Halogen Technical characteristics Brushed stainless steel exterior AISI 316 with ABS frame and glass parts are made from ultra strong scratch proof Ready to install flush mounted The night light is ensured by 4 efficienc...

Page 4: ...osition at a height of 165 cm from the floor to the top edge as indicated in the figure 4 EN 3 Place the product Small Entrance Panel within their back box by pressing on the high and low part of it to facilitate the automatic interlocking 4 To remove the Entrance Panel use the appropriate extraction key Before re install the Entrance Panel close the slot using the appropriate stopper positioning ...

Page 5: ...ed routes with tension cables UTP CAT 5e for outside with protective sheath in PVC All cables must be LSZH for Low Smoke Zero Halogen 5 EN Technical characteristics Brushed stainless steel exterior AISI 316 with ABS frame and glass parts are made from ultra strong scratch proof Ready to install semi surface mounted wall with metal coupling The night light is ensured by 4 efficiency LED Standby pow...

Page 6: ...HT CABLE PIN Code color T568B 1 White orange 2 Orange 3 White green 4 Blue 5 White blue 6 Green 7 White brown 8 Brown 6 EN PROCEDURE 1 SKINNING CABLE 25 30 mm 2 ORDER cable as shown and line up cutting the connectors with scissors at the same height about 10mm 3 INSERT THE CABLE IN CONNECTOR RJ45 as shown in figure 4 CRIMPING WIRE with clamp 5 FINAL CHECK OPERATION with tester Altezza 10mm ...

Page 7: ...rs for system 7 EN To be programmed the basic parameters for system CONCIERGE yes no SOS PANIC BUTTON yes no VIDEO DOOR PHNE VISIBILITY SYSTEM all video intercom device only master video intercom device SYSTEM SETTING TIME GMT 00 SETUP INFINITEPLAY SYSTEM LANGUAGE CHANGE PASSWORD OF SYSTEM default 000000 2 ENTRANCE PANEL To be programmed all parameters of entrance panel in the system IDENTIFICATIO...

Page 8: ... ENTRANCE PANEL Through entrance panel binds the selected function to one or more entrance panel present in the system To a call from entrance panel will be displayed one priority function 8 EN LINK This parameter enables indirect opening of the lock at the same time as the opening of the lock of another entrance panel at the command of an interphone monitor interphone Indirect opening can be asso...

Page 9: ...ercom 1 INTERNAL INTERCOM CALLS Select the list of all internal devices apartment that you can call 2 EXTERNAL INTERCOM CALLS Select the list of the internal intercom of the building that you can call 9 EN DOCTOR MODE yes no When a call comes in this monitor sends the command lock automatically on power supply AUTO ANSWER yes no By activating this function the indoor unit will enter into conversat...

Page 10: ...ault value 20 suggested STAUTS MESSAGE yes no If you set YES the entrance panel show messages Calling in conversation door lock opened end the conversation ENABLE ANIMATION yes no With this function activates an animation in the outdoor unit display that ease the visitor in the use of the outdoor device 10 EN SHOW CODE BUTTON yes no Using this function enables the possibility to activate an automa...

Page 11: ...ol choose how long ANSWERING A CALL 1 VIDEO DOOR PHONE FUNCTION 2 TO END THE CALL 3 MUTE MICROPHONE 4 TO ANSWERING A CALL 1 2 3 5 4 1 2 3 4 11 EN IPCALL VIDEO DOOR PHONE APP 1 VIDEO DOOR PHONE FUNCTION 2 CONCIERCE LIST INTERCOM CONTACT LIST ENTRANCE PANEL LIST LOG ACTIVITIES 3 SETUP AUDIO SETTINGS MESSAGING TO SEND TEXT MESSAGES AND FILES JPG PDF FROM MONITOR TO CONCIERCE AND FROM CONCIERGE TO MON...

Page 12: ... and choose the name to the contacts list Muting the ringtone during a call Mute function When receiving a call from an outdoor entrance panel or from an intercom device the call ringtone can be muted by pressing button MUTE in home page widget You can set the mute time for example 30 minutes 12 EN Door lock command If you press the lock button by home page widget to send a lock opening command to...

Page 13: ...door phone 13 EN P1 Mains 100 240Vac 50 60Hz Entrance panel L P3 P4 P5 CAT5 CAT5 IN2 Stair light IN3 Driveway gate IN3 IN2 1 S AUX1 AUX2 12Vcc 1A Lock AUX1 Stair light AUX2 Driveway gate Power Supply Z6001 Terminals Up to 100mt 1 2 3 4 5 RJ45 Cable CAT 5 Lock 1 5 mm2 Other 1 mm2 Conductor section RJ45 IN4 free IN1 Lock release IN1 P2 Entrance panel Video door phone AUX3 AUX3 free PORTE RJ45 GND N ...

Page 14: ... call button Power 12V Relè additional chime Relè additional chime Power 14 EN P1 Entrance panel L P3 P4 P5 Internet of building CAT5 IN3 IN2 1 S AUX1 AUX2 12Vcc 1A Lock Power Supply Z6001 RJ45 IN1 P2 AUX3 PORTE RJ45 GND N GND GND S Lock return COM 1 COM 2 COM 3 USB IN4 Entrance panel Video door phone USB Mains 100 240Vac 50 60Hz Terminals Up to 100mt 1 2 3 4 5 RJ45 Cable CAT 5 Lock 1 5 mm2 Other ...

Page 15: ...NE AUDIO VIDEO ENTRANCE PANEL WITH TWO PUSH BUTTONS HOME INTERNET 2 P CH1 FP AL PW PW CH2 USB M FIREWALL Distributor Z600F 15 EN Entrance panel Video door phone 1 CAT5 CAT5 RJ45 12Vcc 1A Lock 1 2 P CH1 FP AL PW PW CH2 USB M Power Supply Z6001 Terminals Up to 100mt 1 2 3 4 5 RJ45 Cable CAT 5 Lock 1 5 mm2 Other 1 mm2 Conductor section Internet of building ...

Page 16: ...1 FP AL PW PW CH2 USB M Video door phone Distributor Z60DV Distributor Z60DV Video door phone 16 EN 12Vcc 1A Lock CAT5 CAT5 2 P CH1 FP AL PW PW USB Video door phone Distributor Distributor Z60DV Power Supply Z6001 Internet of building Terminals Up to 100mt 1 2 3 4 5 RJ45 Cable CAT 5 Lock 1 5 mm2 Other 1 mm2 Conductor section Entrance panel CAT5 RJ45 1 ...

Page 17: ...oor phone Entrance panel 2 P CH1 FP AL PW PW CH2 USB M Video door phone Distributor Z60DV Distributor Z60DV Distributor Z60DT 1 1 17 EN CAT5 CAT5 12Vcc 1A Lock CONCIERGE INTERNET of building 12Vcc 1A Lock Distributor Power Supply Z6001 Terminals Up to 100mt 1 2 3 4 5 RJ45 Cable CAT 5 Lock 1 5 mm2 Other 1 mm2 Conductor section ...

Page 18: ...chime Relè additional chime Panic Button Alarm INPUT GND Outdoor call button Power 12V Relè additional chime Relè additional chime Power 18 EN WIRING DIAGRAM DOOR CALL BUTTON Video door phone Contact Push button Sensor 2 P FP RJ45 PW PW USB 2 P CH1 FP RJ45 AL PW PW CH2 USB M ALLARM INPUT to concierge Video door phone Panic Button Alarm INPUT GND Outdoor call button Power 12V Relè additional chime ...

Page 19: ...E RJ45 GND N GND GND GND INPUT S Lock return COM 1 COM 2 COM 3 USB IN4 STAIRS LIGHT CONTOL Mains 90 260Vac 50 60Hz 19 EN P1 L P3 P4 P5 IN3 IN2 S AUX1 AUX2 12Vcc 1A Lock Power Supply Z6001 IN1 Lock release IN1 P2 AUX3 PORTE RJ45 GND N GND GND GND INPUT S COM 1 COM 2 COM 3 USB IN4 WIRING DIAGRAM DOOR RELESE CONTROL wire 1 5mm2 DOOR RELEASE CONTROL Mains 90 260Vac 50 60Hz AUX1 Stair light AUX2 Drivew...

Page 20: ...SMALL INSTALLATION NOTE 20 EN ...

Page 21: ...SMALL INSTALLATION NOTE 21 EN ...

Page 22: ...SMALL INSTALLATION NOTE 22 EN ...

Page 23: ...and electronic equipment or returned to the dealer to purchase a new product For further details regarding the collection systems available contact your local waste disposal service The user is responsible for assigning the equipment purchased to the appropriate collection facilities Risks connected to substances considered as dangerous WEEE According to the WEEE Directive these electrical and ele...