![Infineon WLC1115 User Manual Download Page 3](http://html1.mh-extra.com/html/infineon/wlc1115/wlc1115_user-manual_2055425003.webp)
User Guide
3 of 25
002-35126 Rev. **
2022-05-10
WLC1115 MP-A11 15-W wireless power transmitter
(REF_WLC_TX15W_C1) user guide
Safety information
Safety information
The
REF_WLC_TX15W_C1
reference board is intended for use as an evaluation platform for hardware or
software in a laboratory environment. The board is an open-system design, which does not include a shielded
enclosure. Due to this reason, the board may cause interference to other electrical or electronic devices in close
proximity. In such cases, take adequate preventive measures. Also, do not use this board near any medical
equipment or RF devices.
Attaching additional wiring to this product or modifying the product operation from the factory default may
affect its performance and cause interference with other apparatus in the immediate vicinity. If such
interference is detected, suitable mitigating measures must be taken.
The
REF_WLC_TX15W_C1
reference board contains ESD-sensitive devices.
Electrostatic charges readily accumulate on the human body and any equipment,
which can cause a discharge without detection. Permanent damage may occur to
devices subjected to high-energy discharges. Proper ESD precautions are
recommended to avoid performance degradation or loss of functionality. Store
unused
REF_WLC_TX15W_C1
reference boards in the protective shipping package.
General safety instructions
ESD protection
ESD can damage boards and associated components. Infineon recommends that the user perform procedures
only at an ESD workstation. If an ESD workstation is unavailable, use appropriate ESD protection by wearing an
antistatic wrist strap attached to the chassis ground (any unpainted metal surface) on the board when handling
parts.
Handling boards
The boards provided with the
REF_WLC_TX15W_C1
reference board are sensitive to ESD. When removed from
the casing, this applies to the boards supplied with a plastic casing. Hold the boards only by the edges. Place it
on a grounded, static-free surface after removing a board from the box/casing. Use a conductive foam pad, if
available. Do not slide the board over any surface.
Do’s and
d
on’ts
•
Do not touch the inverter output area marked below while the reference board is
in use. The components in this area may operate at a voltage higher than 30 V
•
Keep the coil area of the reference board clear from any metallic debris
•
Monitor the coil interface
’s