Technical Reference Manual
002-29852 Rev. *B
14.2.27.8 FLASHC_ECC_OVERRIDE
Description:
ECC Data In override information and control bits
Address:
0x4024F030
Offset:
0x30
Retention:
Not Retained
IsDeepSleep:
No
Comment:
The replacement can be either to the Code syndrome or the work flash syndrome. It knows to
replace only 8 bits (per 64) in code flash OR 7 bits (per 32) in work flash, therefore this option
is valid only for pgm64 command (Code) or pgm32 command (Work)
Default:
0x0
Bit-field Table
Bits
7
6
5
4
3
2
1
0
Name
ECC_OVERRIDE_SYNDROME [7:0]
Bits
15
14
13
12
11
10
9
8
Name
None [15:8]
Bits
23
22
21
20
19
18
17
16
Name
None [23:16]
Bits
31
30
29
28
27
26
25
24
Name
ECC
_OVERR
IDE_CODE
[31:31]
ECC
_OVERR
IDE_WORK
[30:30]
None [29:24]
Bit-fields
Bits Name
SW
HW
Default or
Enum
Description
0:7
ECC_OVERRIDE
_SYNDROME
W
R
0
The override syndrome itself to be used in case one of
the enables are set. It will take [7:0] in the case of
Code flash and [6:0] in the case of work flash, to
bypass the internal generated syndrome
30
ECC_OVERRIDE_WORK W
R
0
0: no override. Using internal ECC engine to calculate
the ECC of the Work Flash
31
ECC_OVERRIDE_CODE
W
R
0
0: no override. Using internal ECC engine to calculate
the ECC of the Code Flash
972
2022-04-18
TRAVEO™ T2G Automotive MCU: TVII-B-E-4M body controller entry registers