User Manual
769
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
10-Bit Analog Digital Converter (ADC1)
Measurement Unit 1 Control Register 5
ADC1_CTRL5
Offset
Reset Value
Measurement Unit 1 Control Register 5
1C
H
see
Field
Bits
Type
Description
RES
31:12
r
Reserved
Always read as 0
FILT_OUT_SEL_11_0
11:0
rw
Output Filter Selection for Channels 0 to 11
0000 0000 0000
B
ADC1 Unfiltered Data can be monitored
in the corresponding FILT_OUTx Registers
,
0000 0000 0001
B
Channel 0 IIR Data enabled for
FILT_OUT0 Register
,
0000 0000 0010
B
Channel 1 IIR Data enabled for
FILT_OUT1 Register
,
0000 0000 0100
B
Channel 2 IIR Data enabled for
FILT_OUT2 Register
,
0000 0000 1000
B
Channel 3 IIR Data enabled for
FILT_OUT3 Register
,
0000 0001 0000
B
Channel 4 IIR Data enabled for
FILT_OUT4 Register
,
0000 0010 0000
B
Channel 5 IIR Data enabled for
FILT_OUT5 Register
,
0000 0100 0000
B
Channel 6 IIR Data enabled for
FILT_OUT6 Register
,
0000 1000 0000
B
Channel 7 IIR Data enabled for
FILT_OUT7 Register
,
0001 0000 0000
B
Channel 8 IIR Data enabled for
FILT_OUT8 Register
,
0010 0000 0000
B
Channel 9 IIR Data enabled for
FILT_OUT9 Register
,
0100 0000 0000
B
Channel 10 IIR Data enabled for
FILT_OUT10 Register
,
1000 0000 0000
B
Channel 11 IIR Data enabled for
FILT_OUT11 Register
,
1111 1111 1111
B
For Channels 11-0 IIR Data is enabled for
FILT_OUTx Registers
,
31
16
r
RES
15
12
r
RES
11
0
rw
FILT_OUT_SEL_11_0