Measurement Core Module (incl. ADC2)
ADC or Filter Output Channel 6
Field
Bits
Type
Description
RES
31:10
r
Reserved
Always read as 0
OUT_CH5
9:0
r
ADC or filter output value channel 5
For ADC output set ADC2_FILTUP_5_EN = 0
Table 394 RESET
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_3
00000XXX
H
RESET_TYPE_3
Exact Reset Value:
0000 0000 0000 0000
0000 00XX XXXX
XXXX(B).
ADC2_FILT_OUT6
Offset
Reset Value
ADC or Filter Output Channel 6
68
H
Field
Bits
Type
Description
RES
31:10
r
Reserved
Always read as 0
OUT_CH6
9:0
r
ADC or filter output value channel 6
For ADC output set ADC2_FILTUP_6_EN = 0
Table 395 RESET
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_3
00000XXX
H
RESET_TYPE_3
Exact Reset Value:
0000 0000 0000 0000
0000 00XX XXXX
XXXX(B).
31
16
r
RES
15
10
r
RES
9
0
r
OUT_CH6