User Manual
59
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
Power Management Unit (PMU)
PMU Wake-up Timing Register
These registers are for wake-up control of all wake-up capable general purpose inputs outputs
LIN Wake Enable
PMU_CNF_WAKE_FILTER
Offset
Reset Value
PMU Wake-up Timing Register
0AC
H
Field
Bits
Type
Description
RES
31:4
r
Reserved
Always read as 0.
CNF_GPIO_FT
3:2
rw
Wake-up Filter time for General Purpose IO
Selects the filter time for the Wake-up
00
B
10_us
, 10 µs filter time
01
B
20_us
, 20 µs filter time
10
B
40_us
, 40 µs filter time
11
B
5_us
, 5 µs filter time
CNF_MON_FT
1
rw
Wake-up Filter time for Monitoring Inputs
Selects the filter time for the Wake-up
0
B
20_us
, 20 µs filter time
1
B
40_us
, 40 µs filter time
CNF_LIN_FT
0
rw
Wake-up Filter time for LIN WAKE
Selects the filter time for the Wake-up
0
B
30_us
, 30 µs filter time
1
B
50_us
, 50 µs filter time
Table 16 RESET
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_2
00000000
H
RESET_TYPE_2
PMU_LIN_WAKE_EN
Offset
Reset Value
LIN Wake Enable
050
H
31
16
r
RES
15
4
r
RES
3
2
rw
CNF_GPI
O_FT
11
rw
CNF_
MON*
00
rw
CNF_
LIN*