User Manual
127
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
System Control Unit - Digital Modules (SCU-DM)
7.4.5
Reset Register Description
Reset Control Register
SCU_RSTCON
Offset
Reset Value
Reset Control Register
068
H
Field
Bits
Type
Description
RES
31:8
r
Reserved
Returns 0 if read; should be written with 0.
LOCKUP_EN
7
rwpw
Lockup Reset Enable Flag
Note:
This is a PASSWD protected bit. When the
protection scheme (see
activated (default), this bit cannot be written
directly.
0
B
Lockup is disabled.
1
B
Lockup is enabled.
RES
6:1
r
Reserved
Returns 0 if read; should be written with 0.
LOCKUP
0
rw
Lockup Flag
Note:
This is a PASSWD protected bit. When the
protection scheme (see
activated (default), this bit cannot be written
directly.
0
B
Lockup Status not active.
1
B
Lockup Status active.
Table 54 RESET
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_3
00000000
H
RESET_TYPE_3
31
16
r
RES
15
8
r
RES
77
rwpw
LOCK
UP_*
6
1
r
RES
00
rw
LOCK
UP