Infineon TLE5501 Series Manual Download Page 3

 

3

Rev. 

1.0

 2018-08-01

 

 

TLE5501 Eval Kit

 

General description

1

General description

The Eval Kit consists of:
• an Infineon XMC1100 Boot Kit (microcontroller)
• the TLE5501 Angle Shield which can be plugged onto the Boot Kit
• a “magnetic knob” that can be mounted on top of the shield

Figure 1 Infineon 

XMC1100 

Boot Kit

Figure 2 

TLE5501 Angle Shield

The Eval Kit is complemented by the TLE5501 Eval Kit GUI (Evaluation Kit for Angle Sensors window, see

Figure 3

).

For connection to the PC a micro USB cable is required.

Notes

1. The Eval Kit assumes that the sensor gets 5 V via USB and the integrated regulator on the XMC Boot Kit.
2. All calculations are made with the above assumption! If you create your own setup please also take into 

account VDD monitoring. Please respect the instructions in the TLE5501 E0002 Safety Manual.

Summary of Contents for TLE5501 Series

Page 1: ...ribes the Evaluation Kit for the TLE5501 TMR based angle sensor The purpose of this manual is to describe the software installation process and how to use the TLE5501 angle sensor Evaluation Kit Intended audience This document is intended for anyone who wants to use the TLE5501 Evaluation Kit ...

Page 2: ...e of contents 2 1 General description 3 2 Installation 5 3 Evaluation Kit for Angle Sensors 6 3 1 Connection to PC 6 3 2 Sensor readout 7 3 3 How to calibrate 8 3 4 Safety features 9 3 5 Output buffer 10 4 Revision history 11 Table of contents ...

Page 3: ...Kit Figure 2 TLE5501 Angle Shield The Eval Kit is complemented by the TLE5501 Eval Kit GUI Evaluation Kit for Angle Sensors window see Figure 3 For connection to the PC a micro USB cable is required Notes 1 The Eval Kit assumes that the sensor gets 5 V via USB and the integrated regulator on the XMC Boot Kit 2 All calculations are made with the above assumption If you create your own setup please ...

Page 4: ... TLE5501 sensor is soldered on the shield in a breakout area that can be easily broken of the shield and used in another application if needed The shield has mounting holes for a magnetic knob that can be used to demonstrate the functionality of the sensor The shield has also a voltage buffer available on board and the output of the sensor can be optionally buffered by selecting the correct DIP sw...

Page 5: ... Kit with an USB cable to an USB port on your computer 2 Install the programmer software by double clicking on the file TLE5501_EvalKit_vx msi 3 If you do not have installed Segger Driver NET 3 5 included with this installer install them 4 Start the installed software TLE5501 Eval Kit ...

Page 6: ...After starting the software a device should appear in the Programmer list click the Connect button to connect the Eval Kit In the Sensor drop down list select the sensor TLE5501 and click Start The Evaluation Kit for Angle Sensors window shows the real time angle read out of the sensor and other related information see Figure 3 ...

Page 7: ...r Angle Sensors 3 2 Sensor readout The Evaluation Kit for Angle Sensors window displays the uncalibrated differential angle with the angle gauge It also reports the voltage for each output SinP CosP SinN CosN Figure 3 Evaluation Kit for Angle Sensors window ...

Page 8: ...als sin and cos has to be calibrated to achive high angl eaccuracy This calibration procedure can be performed as described below Click Calibrate The calibration window appears In den calibration window click Ok Rotate the magnet 360 in the direction shown in the calibration window If the red label turns green press Ok Repeat the process for the other direction press Ok ...

Page 9: ...o the safety concept for TLE5501 described in the Product Safety Manual To get all the safety fields populated a calibration is required The external safety mechanisms were implemented in the Eval Kit and violations of the expected values are presented in red If you hover with the mouse over the I icon after performing a calibration you will see more information about the calibration parameters ...

Page 10: ...ensor shield there are 4 DIP switches which allow to select an output buffer for the analog raw signal sin and cos With this buffer enabled a low output impedance is provided For special application e g which high capacitive load this option ispreferred asit avoidsthehigh impedance of theTMR bridge ...

Page 11: ...11 Rev 1 0 2018 08 01 TLE5501 Eval Kit Revision history 4 Revision history Revision Date Changes Rev 1 0 2018 08 01 Initial creation ...

Page 12: ... and any applicable legal requirements norms and standards concerning customer s products and any use of the product of Infineon Technologies in customer s applications The data contained in this document is exclusively intended for technically trained staff It is the responsibility of customer s technical departments to evaluate the suitability of the product for the intended application and the ...