Application Note
18
Rev. 1.0
2017-08-02
TLE5014 Programmer
EEPROM map PWM interface
4.5
Comments
If using SPC bus mode, the first step should be to write the corresponding SPC ID in address 0x00A4
H
The sensor comes with an enabled, default programmed look-up table (LUT) to reach the specified accuracy.
The default LUT values may not be changed as long as no own data are available. A change causes an
increased angle error.
The default values of the LUT can be overwritten in case own data are generated (for e.g. to correct for
magnetic circuit assembly tolerances).
If look-up table is used, the angle base correction (bit [15:2] of address 0x00A0
H
) has to be performed before
look-up table values are modified.
No other bits as the described may be changed as this could cause an unpredictable sensor behavior.