TC1796
Peripheral Units (Vol. 2 of 2)
Micro Link Interface (MLI)
User’s Manual
23-97
V2.0, 2007-07
MLI, V2.0
The Transmitter Command Register TCMDR contains the command codes that are used
during Command Frame transmission. Each time one of the CMDPx bit fields is written,
a Command Frame transmission is triggered. Independent of the transferred command
code value, a Command Frame transmitted event can be generated in the transmitter for
each pipe and a Command Frame received event for each pipe in the receiver,
respectively.
TCMDR
Transmitter Command Register
(28
H
)
Reset Value: 0000 0000
H
31
28 27
24 23
20 19
16 15
12 11
8 7
4 3
0
0
CMDP3
0
CMDP1
0
CMDP1
0
CMDP0
r
rw
r
rw
r
rw
r
rw
Field
Bits
Type Description
CMDP0
[3:0]
rw
Command Code for Pipe 0
This bit field contains the command code related to
pipe 0. The pipe 0 command codes allow an activation
(pulse) of one of the service request outputs SR[3:0] in
the receiving controller.
0001
B
Activate service request output SR0
0010
B
Activate service request output SR1
0011
B
Activate service request output SR2
0100
B
Activate service request output SR3
Other bit combinations are reserved for future use; no
further action occurs in the receiver.
CMDP1
[11:8]
rw
Command Code for Pipe 1
This bit field contains the command code related to
pipe 1. The pipe 1 command codes allow to adjust the
receiver delay for the parity error condition (see
RCR.DPE) in the MLI receiver of the receiving controller.
0000
B
Set RCR.DPE = 0000
B
0001
B
Set RCR.DPE = 0001
B
…
B
…
1110
B
Set RCR.DPE = 1110
B
1111
B
Set RCR.DPE = 1111
B