Declaration Of Conformity
This is to certify that this equipment, designed and manufactured by INFICON® Inc., Two
Technology Place, East Syracuse, NY 13057 USA, meets the essential safety requirements of
the European Union and is placed on the market accordingly. It has been constructed in
accordance with good engineering practice in safety matters in force in the Community and
does not endanger the safety of persons, domestic animals or property when properly installed
and maintained and used in applications for which it was made.
Equipment Description . . . . . . . . . . . . . . D-TEK Select
Refrigerant Leak Detector
Applicable Directives . . . . . . . . . . . . . . . 2006/95/EC (LVD)
2004/108/EC (EMC)
2011/65/EU (RoHS)
2006/66/EC as amended by 2013/56/EU (Battery
Directive)
Applicable Standards . . . . . . . . . . . . . . . EN 61010-1:2010;
EN 61326-1:2013 (Class A);
EN 62133:2013 (CB Test Cert. FI-17925)
CE Implementation Date. . . . . . . . . . . . . March 9, 2015
Authorized Representative . . . . . . . . . . . Brian King
Business Line Manager, Service Tools
INFICON Inc.
Any questions relative to this declaration or to the safety of INFICON products should be
directed, in writing, to the quality assurance department at the above address.
WARNING
This symbol is used to alert the user to the presence of important operating
and maintenance (servicing) instructions in the literature accompanying this
instrument.
INFICON® and D-TEK™ Select are trademarks of INFICON.
Specification Table in Accordance with EN 14624
Minimum sensitivity to R134a, fixed (static)
1 g/yr
Maximum sensitivity to R134a, fixed (static)
>50 g/yr
Minimum sensitivity to R134a, moving (dynamic)
1 g/yr
Maximum sensitivity to R134a, moving (dynamic)
>50 g/yr
Minimum response/detection time
<1 second
Zering time
5-7 seconds
Recovery time for 50 g/yr exposure*
1 second
Minimum sensitivity in contaminated environment
2 g/yr
Calibration frequency: Check annually with calibrated leak standard.
*Upper leak detection limit is not specified by INFICON as there is no upper limit to the size
of the leak the detector is able to detect. As no 50 g/yr leak standard was available during
testing, a 31 g/yr leak was substituted.