iNetVu Troubleshooting Guide - 1201 Flyaway
Page 39 of 71
c. If we are getting voltage from the 7000 controller
, we will need to test voltage on the flyaway
control cable. Reconnect the motor cable to the controller and disconnect the control cable from
the base plate of the platform. Place the volt meter leads on pins C and D of the control cable.
Using the 7000 controllers front panel, select Elevation with HI SPEED on and hold +. Are you
getting 24VDC? If no voltage is shown, it concludes the cable needs to be replaced. Contact C-
COM Technical Support for further assistance.
d. If we are getting voltage from the control cable
, reconnect the Control Cable to the platform
and verify the Elevation Motor cable is securely connected as seen below.
Internal Elevation Motor and Tilt (Inclinometer) Sensor Cables
e.
Reseat this cable and try to move the platform on elevation. If the platform does not move please
Contact C-COM Technical Support for further assistance.
Summary of Contents for 1201 Flyaway
Page 15: ...iNetVu Troubleshooting Guide 1201 Flyaway Page 15 of 71 Assembly and Disassembly...
Page 16: ...iNetVu Troubleshooting Guide 1201 Flyaway Page 16 of 71 Fly 1201 Physical Outline...
Page 41: ...iNetVu Troubleshooting Guide 1201 Flyaway Page 41 of 71 Flyaway Control Cable...
Page 45: ...iNetVu Troubleshooting Guide 1201 Flyaway Page 45 of 71 Flyaway Control Cable...
Page 49: ...iNetVu Troubleshooting Guide 1201 Flyaway Page 49 of 71 Flyaway Control Cable...
Page 50: ...iNetVu Troubleshooting Guide 1201 Flyaway Page 50 of 71 SENSOR ERROR...
Page 54: ...iNetVu Troubleshooting Guide 1201 Flyaway Page 54 of 71 GPS...
Page 57: ...iNetVu Troubleshooting Guide 1201 Flyaway Page 57 of 71 RF SIGNAL LOSS...
Page 63: ...iNetVu Troubleshooting Guide 1201 Flyaway Page 63 of 71 MODEM...
Page 67: ...iNetVu Troubleshooting Guide 1201 Flyaway Page 67 of 71 CANNOT FIND SATELLITE...