background image

CHARGING YOUR APEX

The Apex has two ports for charging. Only connect one 
charge source at a time, connecting two simultaneously 

will damage your Apex and may be dangerous.

 

•Port 1:

 

Low current charge input for use with the included 

Inergy Standard Wall Charger or Apex Car Charger ONLY.

DO NOT USE FOR SOLAR CHARGING.

  Both the Standard Wall 

Charger and Apex Car Charger have a small LED light on the pow-
er supply that will turn red when the system is charging.  Once 
the light turns green, the system is fully charged.  Another way 
to verify the system is charging is by turning the Power Switch 
to DC ONLY mode (see page 3 for more information).  The LCD 
should display 

CHG

 in the top middle to indicate the system is 

charging, and the Wattage figure on the top right will display the 
charge rate in Watts.

•Port 2:

 

High current charge input for use with the Apex Quick 

Wall charger and Inergy solar panels.

MAXIMUM INPUT:

  UP TO 500 WATTS, NOT TO EXCEED 26 VOLTS 

DC (OPEN CIRCUIT, ABBREVIATED AS VOC) or 30 AMPS.  When a 
charge source is connected to Port 2, the blue charge indicator 
LED will illuminate to indicate the system is charging.  Another 
way to verify the system is charging is by turning the Power 
Switch to DC ONLY mode (see page 3 for more information).  The 
LCD should display CHG in the top middle to indicate the system 
is charging, and the Wattage figure on the top right will display 
the charge rate in Watts.

Charging with Solar Panel(s)

Charge times vary depending on solar panels used, sun condi-
tions, and angle of panel(s) relative to the sun.  If using third 
party panels not supplied by Inergy, always connect panels in a 
PARALLEL wiring configuration - 

not a SERIES wiring configu-

ration.

  See PAGE 8 “Solar Energy General Guidelines.”

Charging with Standard or Quick Wall Charger

 

-The provided Standard Wall Charger

 is a 100 Watt charge source, 

taking approximately 11 hours to fully recharge. Connect to Port 1. 

-The Quick Wall Charger 

is a 189 Watt charge source, taking approxi-

mately 6 hours to fully recharge the Apex.  Connect to Port 2.

Charging with Car Charger

Using a vehicle’s 12V DC socket charges the Apex at up to 113 
Watts, taking approximately 10-11 hours to fully recharge. Con-
nect car charger to Port 1.

USING YOUR APEX

The Apex has a 3-position power switch that allows only specific 
output ports to be activated based on your needs.  The Apex can 
be charged with the 3 position power switch in any position.  See 

the illustration and descriptions below for more information:

3

2

LEFT POSITION: 

All DC ports (12V DC sockets, Basecamp LED 

Light ports, and the USB ports) on, otherwise referred to as DC 
ONLY mode.  This will also activate the LCD Display.

MIDDLE POSITION: 

 All output ports off, otherwise referred to 

as OFF mode.

RIGHT POSITION: 

 All AC & DC ports on, otherwise referred to 

as ALL ON mode.  This will also activate the LCD display.

Summary of Contents for APEX

Page 1: ...APEX USER MANUAL POWERFORLIFE ...

Page 2: ... to a full year however we recommend checking the battery level every 3 months to ensure it is over 10 charged Q Can I use the Apex while it is charging A Yes It s capable of outputting power while charging Q Can I fly on an airplane with the Apex or ship it myself A No The Apex cannot be carried on or checked onto passenger aircraft Similarly due to the size of the internal lithium battery shippi...

Page 3: ... is charging and the Wattage figure on the top right will display the charge rate in Watts Charging with Solar Panel s Charge times vary depending on solar panels used sun condi tions and angle of panel s relative to the sun If using third party panels not supplied by Inergy always connect panels in a PARALLEL wiring configuration not a SERIES wiring configu ration See PAGE 8 Solar Energy General ...

Page 4: ...t was under stress They are labeled as AC DC 1 and DC 2 Simply reset the breaker by allowing it to cool for several min utes then press it back into place Reduce the power demand on the Apex and you re good to go Reading the LCD Display The LCD Display is activated by the power switch in both DC mode DC ONLY or AC DC mode ALL ON A fully charged Apex will be between 12 3 12 6 Volts A completely dis...

Page 5: ...ut 12 5 Amps 3 000 Watt starting surge maximum Connector Type Nema TT 30R F 12V DC Sockets 180 Watts 15 Amps maximum continuous output per socket G USB Ports USB C PD 5V 3A 9V 2A 12V 1 5A USB A QC 3 0 5V 3A 9V 2A 12V 1 5A NOTE For full quick charge or power delivery performance the Apex battery must be charged over 12 Volts H Basecamp LED Light Ports 12V DC output Connect up to 10 Base camp LED Li...

Page 6: ...general rule of thumb the brighter the sun is shining and the clearer the day the better solar panels will work Panels op erate at peak efficiency when the sun is most direct typically around midday Solar panels run off of light not heat In fact solar panels pro duce the most during cold clear days rather than in extremely hot conditions Even during windy or rainy conditions they are able to funct...

Page 7: ...TTERIES MUST BE WITHIN 0 1 VOLTS OF APEX VOLTAGE 10 4 VOLTS 10 6 VOLTS BEFORE CONNECTING FAILURE TO DO SO VOIDS THE WARRANTY AND CAN RESULT IN IRREPARABLE DAMAGE TO THE APEX AND OR RISK OF FIRE External batteries should be connected in a PARALLEL wiring configuration to expand the battery capacity of the Apex see page 13 for more information This is done by connecting positive to positive and nega...

Page 8: ...nect an external battery ensure the external battery measures between 10 4 10 6 Volts before it is connected A Voltage meter available at local hardware or auto parts store can be used to measure your external batteries IMPORTANT NOTICE REGARDING LITHIUM BATTERIES In general devices with large quantities of lithium ion batteries like the Apex should be stored similar to a gas powered gen erator aw...

Page 9: ...rkmanship and material under normal consumer use during the applicable warranty period identified in Paragraph 2 below subject to the exclusions set forth in Paragraph 6 below This warranty statement sets forth INER GY SOLAR s total and exclusive warranty obligation We will not assume nor authorize any person to assume for us any other liability in connection with the sales of our products WARRANT...

Page 10: ...880 N 5th Ave Pocatello ID 83201 INFO INERGYSOLAR COM 877 891 2657 POWERFORLIFE ...

Reviews: