Settings
Function P5, Pause during the main time
Setting “00”: Pause during the main time impossible
Setting “01”: Pause during the main time possible
Note, During a pause situation the remaining time will be intermittently indicated (if display indication
is activated (P3)).
Function P6, Main time during the pause
Setting “00”: Main time stops during the pause
Setting “01”: Main time continues during the pause
Function P7, Main time reduction during the main time
Setting “00”: The main time will be finished immediately when the STOP key is pressed.
Setting “01”: It is possible to shorten the main time during the main time (by means of the stop key).
When the main time is shortened it will always start with whole minutes.
Note: When activating this function, function P4 has to be connected as well (even if the pre-time is
not used).
Setting “02”: The Stop key will be blocked during the main time. During the pre-time, it will function as
programmed in function P4.
Function P8, Main time extension during the main time
Setting “00”: It is not possible to extend the main time during the main time.
Setting “01”: It is possible to extend the main time during the main time.
Note: The maximum amount of start pulses can be programmed in function F4.
Specifications
Supply voltage for the network model:
Voltage range:
185 VAC - 240 VAC
Current consumption:
25 mA maximum
Fuse 500mA
Supply voltage for the low voltage model
Voltage range:
12 VAC - 24 VAC
12 VDC - 35 VDC
Current consumption:
250 mA maximum
Maximum rupturing capacity of the relay:
6,3 ampere max.
with
cosine
phi=0,4
Admissible rupturing capacity of the relay:
6,3 ampere max.
with
cosine
phi=0,4
SunTimer
®
2400 Version 3.0 25-01-2008
-
www.inepro.com
-