7 - PayMatic P2000
Installation
Connect the wiring to the indicated positions on the terminal strip.
Make sure the connection wires leave as short as possible the
machine housing.
Aansluitingen:
Solution
Contact
Usage
1
Normally closed
(n.c.) contact
Use the brown (1) and the green (2)
cable marked on the terminal
strip.
2
Normally open
(n.o.) contact
Use the brown (1) and the y ellow
(3) cable marked on the terminal
strip.
Voltage / current microswitch;
250Vac, 4A resistive / 1A inductive
Switching time
The switching time of the microswitch
depends on two factors, the size of the
inserted coin and its rate of fall.
Nevertheless, with independence of
these two variable factors, the activation
time of the microswitch is always from
20 ms to 200 ms.
The device has to be connected by authorised and
prepared personnel only!