Safety
[email protected] | www.romanoff.com
2019-10-16
2
–7
Danger!
Risk of burns. If metal is melted without the supply of protective gas,
can cause a flash fire or explosion when opening the bell.
Melt at temperatures above 500 °C always with protective gas. Use
as a protective gas exclusively argon or nitrogen
Danger!
Danger because of touching parts conducting voltage.
Work on the electrical equipment is only allowed for au-
thorized qualified staff.
Access to the electrical distribution box is only allowed
for authorized qualified staff with tool.
Work on the electrical equipment is only allowed when
the system is disconnected from power supply (pull out
mains plug).
The capacitors can retain their charge even after de-
activation of the system.
Keep the housing of the mini-casting unit closed con-
tinually.
No work must be carried out on parts conducting high
voltage.
Remove loose connections.
Replace immediately damaged scorched or slightly
burned cables. Perform work only when mains plug is
pulled out.
Cables may not wedge in or rather squeezed. Cables
have to be laid in a way that they not become a trip-
ping hazard or can be not damaged.
Danger!
Threat of health injury by escape of medias from damaged hoses.
Danger of system damages.
Remove loose connections. Replace damaged hoses immediate-
ly. Perform work only when mains plug is pulled out.
Hoses may not wedge in or rather squeezed. Hoses have to be
laid in a way that they not become a tripping hazard or can be not
damaged.
Warning!
Risk of burns:
burns because of squirting liquid metal and
burns at hot surfaces.