3
S
AFETY
D
O NOT USE EQUIPMENT WITH THIS TOOL THAT IS NOT RECOMMENDED OR SUPPLIED BY
I
NDUSTRIAL
R
IVET
&
FASTENER
C
O
.
A
LWAYS DISCONNECT THE AIR SUPPLY BEFORE ATTEMPTING ANY MAINTENANCE OR ADJUSTMENT
/
FITTING OF NOSE EQUIPMENT
D
O NOT OPERATE A TOOL THAT IS DIRECTED TOWARDS ANY PERSON
(
S
)
A
LL MODIFICATIONS CARRIED OUT ON THE TOOL WITHOUT THE CONSENT OF
I
NDUSTRIAL
R
IVET
&
FASTENER
C
O
.
SHALL BE
DONE SO AT THE CUSTOMERS
’
SOLE RESPONSIBILITY
R
EFER TO THIS MANUAL BEFORE ATTEMPTING ANY MAINTENANCE OPERATION
A
VOID EXCESSIVE CONTACT WITH HYDRAULIC OIL
(Velocite No 10)
,
AS SOON AS POSSIBLE WASH HANDS THOROUGHLY
D
O NOT EXCEED
7
BAR
/
100
PSI INLET PRESSURE
,
THE USE OF A PRESSURE REGULATOR IS HIGHLY RECOMMENDED
I
NSPECT THE MANDREL REGULARLY
.
W
HILE SOME MARKING THROUGH USE IS NORMAL EXCESSIVE PITTING AND DISTORTION
MAY CAUSE A MANDREL TO FAIL
.
A
MANDREL THAT FAILS MAY FORCIBLY EJECT FROM THE TOOL
.
M
ANDRELS SHOULD BE
INSPECTED BEFORE THE RECOMMENDED NUMBER OF PLACINGS BASED UPON THE BROACH LOAD OF THE PARTICULAR
APPLICATION
.
I
F YOU ARE UNSURE OF THE BROACH LOAD CONATCT YOUR
I
NDUSTRIAL
R
IVET
&
FASTENER
C
O
.
REPRESENTATIVE
WHO WILL HELP YOU DETERMINE WHAT THIS IS AND THE SAFE NUMBER OF PLACINGS TO EXPECT FROM THE MANDREL
S
PECIFICATIONS
The specifications and information contained in this manual are applicable only to the tool with which it was
supplied. Industrial Rivet & Fastener Co reserve the right to make any changes without notice as part of
Industrial Rivet & Fastener Co policy of continuous improvement.
S
PECIFICATIONS FOR
RK-753™
I
NTENSIFIER
/
B
OOSTER
Air Pressure
Min/Max
□
5 – 7 bar
□
70 – 100 psi
Intensification Ratio
□
30 : 1
□
S
PECIFICATIONS FOR
RK-753™
R
IVET
T
OOL
Air Pressure
Min/Max
□
5 – 7 bar
□
70 – 100 psi
Free Air Volume Required
@5.1 bar/75psi
□
2.6
liters
□
.09
ft
Stroke Minimum
□
30
mm
□
Pull Force
@5.5 bar/80psi
□
3.89kN
□
Cycle Time
Approximately
□
1-1.5
seconds
□
Noise Level
Less than
□
70
dB(A)
□
Weight
□
1.2kg
□
2.64
lb
Vibration Less
Than
□
2.5
m/s
□
8
ft/s