Additional Information 

For installation instructions see Install Guide.
For compressor package wiring diagram contact manufacturer.
For compressor parts breakdown see website (compressed-air-systems.com) of contact  

compressor manufacturer.
On electric driven compressors always follow NEC (National Electric Code) on any local applicable code 

that exceeds NEC guidelines.
On gas/diesel engine driven packages follow engine manufacturer guide for proper placement  

and installation of engine driven equipment.

WARNING: 

Always wear proper protective eye ware, hearing protection and safety clothing when 

working around the compressor package. No loose or baggy clothing should be worn around  

compressor package at any time.

WARNING:

 On Electric motor powered air compressors make sure electrical system is up to National 

Electric Code (NEC) prior to installing compressor system. Failure to install a compressor with a proper 

NEC electrical system can cause personal injury, compressor package damage and void compressor 

package warranty

NOTICE: 

To ensure full compressor tank warranty all tank mounted compressor packages must be 

mounted on factory approved vibration isolation pads. A compressor should NEVER be installed while 

still on or in its original packaging. Failure to properly install the compressor system with approved 

vibration isolation pads will result in the compressor tank warranty being void.

WARNING:

 Compressed Air Systems compressors can operate at pressures from 0-250psi depending 

on the compressor package design and build specifications. Always verify that the system the  

compressor is installed into can handle the maximum operational pressure the compressor. NEVER 

install a compressor in a system that can not handle the compressors maximum operating pressure.

WARNING:

 Compressed air is extremely dangerous when not properly used or installed. Always make 

sure a trained compressed air professional has looked over the air system prior to use. Improper  

installation or use of compressed air can cause bodily injury or death. NEVER pressurize an object that 

was not designed to be pressurized. Pressurizing objects not properly engineered for the maximum  

operating pressure of the compressor system can cause bodily injury or death.

Industrial Gold Air Compressors  

|

 800-531-9656  |  www.industrialgold.com

G43 Pump

Summary of Contents for G43

Page 1: ...OMPRESSOR WILL NOT BE LIABLE FOR ANY DAMAGE BECAUSE OF FAILURE TO FOLLOW THE INSTRUCTIONS IN THIS MANUAL By following the instructions and recommendations in this manual you will ensure a longer and s...

Page 2: ...or soldered joints in any part of the compressed air system Failure to ensure system compatibility with compressor piping is dangerously unsound Never use a flammable or toxic solvent for cleaning the...

Page 3: ...ned compressed air professional has looked over the air system prior to use Improper installation or use of compressed air can cause bodily injury or death NEVER pressurize an object that was not desi...

Page 4: ...ks or add another unit to handle the excess demand Compressor overheating Poor ventilation Dirty cooling surfaces Compressor is out of its operating duty cycle Relocate compressor to any area with bet...

Page 5: ...nsion this is done to ensure the belt do not fail pre maturely tighten them as needed to ensure they do not slip If belts are loose tighten per instructions on next page Failure to tighten can cause p...

Page 6: ...ed to as a single stage pump Single stage units normally are used in the 90 to 125psi range and are available as single or multi cylinder twin cylinder compressors When the air drawn from the atmosphe...

Page 7: ...age or personal injury Follow good shop practices and safety procedures Receiving and Uncrating of your Compressor BEFORE UNCRATING THE COMPRESSOR THE FOLLOWING STEPS SHOULD BE TAKEN 1 Immediately upo...

Page 8: ...or It should line up without having to spring or twist into position Adequate expansion loops or bends should be installed to prevent undue stresses at the compressor resulting from the changes betwee...

Page 9: ...ed to carry the full motor current load The coil which engages and disengages the contact points in the motor starter is controlled by the pressure switch Never attempt to bypass the pressure switch o...

Page 10: ...maintenance to be performed in a safe manner Never substitute a check valve for a manual shut off valve block valve if the purpose is to isolate the compressor from a system for servicing CAUTION CAU...

Page 11: ...the operator and maintenance personnel If for any reason any part of the manual becomes illegible or if the manual is lost have it replaced immediately The instruction manual should be periodically r...

Page 12: ...tch button to check the rotational direction of the compressor It should agree with the rotation arrow on the flywheel pulley counter clockwise facing the shaft The following procedures should be foll...

Page 13: ...125 degrees F can burn the skin some surface temperatures exceed 400 degrees F when the compressor is working 6 Clean up all oils spills immediately to prevent slipping Mark spill area accordingly CAU...

Page 14: ...Bar 12 Rpm 860 Cylinders 120X2 100X1 Bore inch 4 72 3 94 mm 120 100 Stroke inch 3 15 mm 80 Flywheel dia inch 13 78 mm 350 Groove Type B Dimensions A inch 15 59 mm 396 B inch 8 98 mm 228 C inch 6 85 mm...

Page 15: ...SINO USA DAFENG LIDA COMPRESSED AIR SYSTEMS CO LTD MODEL G43 Two Stage Air Compressor Pump Industrial Gold Air Compressors 800 531 9656 www industrialgold com G43Pump...

Page 16: ...43 1 a 17 431006 OIL SIGHT GLASS GS43 1 18 431007 OIL DRAIN PLUG GS22 1 19 431008 BEARING FRONT 32210 1 20 431009 CAPSCREW HEX M16X80 2 21 431010 LOCKWASHER 16 2 22 431011 BEARING REAR 30310 1 23 4310...

Page 17: ...48 431033 GASKET CYLINDER TO CRANKCASE GS43 3 a 49 431034 CAPSCREW HEX M12X35 24 50 431035 GASKET CYLINDER HEAD GS43 2 a 51 431035 1 GASKET CYLINDER HEAD GS33 1 a 52 431036 VALVE COPPER GASKET GS43 4...

Page 18: ...GS12 5 72 431048 COPPER SEAL RING GS43 5 73 431049 ALUMINUM TUBE 6 GS43 2 74 431050 TEE MALE TUBE GS12 2 75 431051 NUT COMMPRESSION GS43 1 76 431052 ELBOW GS43 3 77 431053 TEE GS43 1 78 431054 INTERCO...

Page 19: ...nk warranty all tank mounted compressor packages must be mounted on factory approved vibration isolation pads A compressor should NEVER be installed while still on or in its original packaging Failure...

Page 20: ...Industrial Gold LLC 10 2016 2626 Skyway Drive Grand Prairie TX 75052 417 206 6353 800 531 9656 Fax 417 206 6336 QualityAirCompressorataGreatPrice...

Reviews: