ELECTRICAL POWER REQUIREMENTS
SPÉCIFICATIONS D’ALIMENTATION ÉLECTRIQUE
ESPECIFICACIONES DE ALIMENTACIÓN ELÉCTRICA
ELECTRICAL WIRING
Refer to the air compressor’s serial label for the unit’s voltage
and amperage requirements.
Use a dedicated circuit
For best performance and reliable starting, the air
compressor must be plugged into a dedicated circuit, as close
as possible to the fusebox or circuit breaker.
The compressor
will use the full capacity of a typical 15 amp household circuit. If
any other electrical devices are drawing from the compressor’s
circuit, the compressor may fail to start. Low voltage or an
overloaded circuit can result in sluggish starting that causes the
motor overload protection system or circuit breaker to trip,
especially in cold conditions.
NOTE:
A circuit breaker is recommended. If the air
compressor is connected to a circuit protected by a fuse, use dual
element time delay fuses (Buss Fusetron type “T” only).
ELECTRICAL CORDS
NOTE:
Avoid use of extension cords.
For optimum performance, plug the compressor power cord
directly into a grounded wall socket. Do not use an extension cord
unless absolutely necessary. Instead, use a longer air hose to
reach the area where the air is needed.
If use of an extension cord cannot be avoided, the cord
should be no longer than 50 feet and be a minimum wire size of 12
gauge (AWG). Do not use a 16 or 14 gauge extension cord.
Use only a 3-wire extension cord that has a 3-blade grounding
plug, and a 3-slot receptacle that will accept the plug on the
product. Make sure your extension cord is in good condition. An
undersized cord will cause a drop in line voltage, resulting in loss
of power and overheating. The smaller the gauge number, the
heavier the cord.
GROUNDING INSTRUCTIONS
This product should be grounded. In the event of an electrical
short circuit, grounding reduces the risk of electric shock by
providing an escape wire for the electric current.
This product is equipped with a cord having a grounding wire
with an appropriate grounding plug. The plug must be plugged into
an outlet that is properly installed and grounded in accordance with
all local codes and ordinance.
DANGER
Improper installation of the grounding
plug can result in a risk of electric shock. If repair or
replacement of the cord or plug is necessary, do not
connect the grounding wire to either flat blade
terminal. The wire insulation having an outer surface
that is green with or without yellow stripes is the
grounding wire.
This product is for use on a nominal 115 volt circuit. A cord
with a grounding plug, as shown here, shall be used.
Make sure that the product is connected to an outlet having
the same configuration as the plug (see
Figure 4
). No adapter
should be used with this product.
Check with a licensed electrician if the grounding instructions are
not completely understood, or if in doubt as to whether the product
is properly grounded. Do not modify the plug provided; if it will not
fit the outlet, have the proper outlet installed by a licensed
electrician.
CÂBLAGE ÉLECTRIQUE
Pour les normes de tension et d’intensité de courant de l’unité,
veuillez référer à l’étiquette de série du compresseur d’air.
Utilisez un circuit spécialisé
Pour obtenir un rendement optimum et une mise en
marche fiable, le compresseur doit être branché sur un circuit
spécialisé (unique),
le plus près possible de la boîte à fusibles ou
du disjoncteur. Le compresseur utilisera la pleine capacité d’un
circuit domestique typique de 15 ampères. Si d’autres appareils
électriques sont branchés sur le circuit du compresseur, celui-ci
pourrait ne pas se mettre en marche. Une basse tension ou un
circuit surchargé pourrait provoquer une mise en marche difficile et
ainsi déclencher le dispositif de protection contre les surcharges
du moteur ou le disjoncteur, tout spécialement par températures
froides.
REMARQUE :
L’usage d’un disjoncteur est recommandé. Si
le compresseur d’air est branché à un circuit protégé par un
fusible, utilisez un fusible à élément double à action lente
(seulement Buss Fusetron de type « T »)
CÂBLES ÉLECTRIQUES
REMARQUE :
Évitez d’utiliser des rallonges
Pour obtenir un rendement optimum, branchez le câble
électrique du compresseur directement à une prise de courant
murale équipée d’une mise à la terre. N'utilisez pas de rallonge
sauf en cas de nécessité absolue. Utilisez plutôt un tuyau d’air
plus long pour atteindre la zone où l'air est requis.
S’il est impossible d’éviter l’usage d’une rallonge, celle-ci ne
devrait pas excéder 15,2 m de longueur et comporter un fil de
calibre 12 minimum (AWG). N’utilisez pas une rallonge de calibre
16, ni 14.
Utilisez seulement une rallonge à 3 fils munie d'une fiche à 3
lames avec mise à la terre et une prise de courant à 3 fentes dans
laquelle la fiche de l’unité peut être branchée. Assurez-vous du
bon état de la rallonge utilisée. Une rallonge comportant un faible
calibre produira une baisse de tension sur la ligne et provoquera
une perte de puissance et une surchauffe. Plus le calibre est petit,
plus le câble est robuste.