Indunium 2i User Guide
34 / 77
3.2.11
Modbus
This tab describes Digital Output settings.
Networks
Item
Description
Default
Enable
Tick to enable Modbus RTU Slave function in the modem.
Disable
Slave ID
Modbus slave ID, input from 1 to 247.
1
Coil Address
Modbus address to read coils (0x01) or wire single coil (0x05).
Input from 0 to 65535.
0
Register Address
Modus address to read holding register (0x03) or write single
register (0x05).
Input from 0 6o 65535
0
PLC Send SMS
Tick to enable.
The PLC will poll the modem to send SMS, in which the SMS
content and phone number can be set by PLC.
Disable
Send
SMS
Function
Code
(0x05)
Read only parameters.
The function code for sending SMS.
Set SMS Function
Code (0x10)
Read only parameters.
The function code for setting SMS content and phone number.
Phone
Number
Address
The start address to save phone number, total 16 registers.
SMS
Content The start address to save SMS content, total 35 registers.