Indunium 2i User Guide
24 / 77
SMS advertisements.
Induo’s proprietary SMS Direct has the following features:
1. Transparently converts serial data to short message or vise versa without using AT Commands.
2. Text, binary, and Unicode formats are supported.
3. Verification of Incoming Caller ID is implemented to block uncertified users.
4. The configuration profile can be easily stored, and then copied to other modems.
The follow table introduces the SMS Direct function.
SMS Direct
Note: This function is only available under “Config Mode”.
Item
Description
Default
Enable
SMS-IN
Tick the SMS-IN checkbox to allow forwarding of incoming short messages
from specified Caller ID to the modem’s serial port as data.
The Caller ID (phone number) should be specified in “Phone Book” tab by
inputting the phone number and tick “SMS In” checkbox.
Disable
Enable
SMS-OUT
Tick the SMS-OUT checkbox to allow data received from the attached serial
device to be transmitted as short messages to Target Phone Number.
The Target Phone Number (phone number) should be specified in “Phone
Book” tab by inputting the phone number and tick “SMS Out” checkbox.
Disable
Text ASCII
7 bits text format (160 bytes per packet)
Disable
From Mobile
Enable when receiving text (ASCII) SMS from mobile phone.
Disable when receiving text (ASCII) SMS from mobile phone.
Disable
To Mobile
Enable when sending text (ASCII) SMS from mobile phone.
Disable when sending text (ASCII) SMS from mobile phone.
Disable
Unicode
(UCS2)
16 bits Unicode (UCS2) format (70 bytes per packet)
Disable
Binary (8 bits)
8 bits binary (140 bytes per packet)
Disable
Auto
Add
Timestamp
Auto adds timestamp at the beginning of the SMS.
Timestamp format is dd.mm.yy hh:mm:ss
Disable
Max. SMS/Day
Set daily limitation for sending SMS in SMS Direct function, when reaching the
maximum limitation, INDUNIUM 2I will stop sending SMS any more at that day.
0 is no limitation.
Customer could also clear the counter by sending SMS to INDUNIUM 2I with
SMS Control privilege, the SMS is “clear sms counter”
0