2.7. aqua PriMa
If the “aqua prima” filter is selected from the user
menu or the control panel, the system’s water
metering logic functions as follows:
If the “aqua prima” function is
enabled
, the electronic
control system performs a pulse count of the turbine,
recording
one pulse every 2 revolutions
.
If the “aqua prima” function is
disabled
, the electronic
control system performs a pulse count of the turbine,
recording
one pulse every revolution
.
The graph in the figure below illustrates this
function:
decalciFicaTiOn
hardness
water hardness
decalcification
frequency
decalcification
frequency with use
of aqua Prima
1
Soft water (up to 7ºdh)
Approx. 3 months 120 litres Approx. 3 months 240 litres
2
medium water (7º-14ºdh)
Approx. 2 months 90 litres Approx. 2 months 180 litres
3
hard water (15º-21ºdh)
Approx. 6 weeks 60 litres
Approx. 6 weeks 120 litres
4
Very hard water (over 21ºdh) Approx. 4 weeks 30 litres
Approx. 4 weeks 60 litres