TECHNICAL SPECIFICATIONS
ENERGY LABEL
Directive 2002/40/EC on the label of electric ovens
Norm EN 50304
Energy consumption for Natural convection
heating mode:
Convection
Declared energy consumption for Forced convection Class
heating mode:
Fan assisted (mod. KP 958 MS.B)
This appliance conforms with the following European Economic
Community directives:
-
73/23/EEC of 19/02/73 (Low Voltage) and subsequent modifications;
-
89/336/EEC of 03/05/89 (Electromagnetic Compatibility) and
subsequent modifications;
-
90/396/EEC of 29/06/90 (Gas) and subsequent modifications;
-
93/68/EEC of 22/07/93 and subsequent modifications.
Oven accessories which may come into contact with food
are make in materials complying to what is laid down in
EEC Directive 89/109 of 21.12.88 and national regulations
in force.
BURNERS AND NOZZLES SPECIFICATIONS
• the supply system is efficiently earthed according to
standards and laws in force;
• the socket or double-pole switch are easily accessible when
the appliance is installed.
Important: the wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow
- Earth
Blue
- Neutral
Brown
- Live
As the colours of the wires in the mains lead may not
correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
Connect the Green & Yellow wire to terminal marked “E” or
or coloured Green or Green & Yellow.
Connect the Brown wire to the terminal marked “L” or coloured
Red.
ELECTRICAL CONNECTION
Connect the Blue wire to the terminal marked “N” or coloured
Black.
The cable of this appliance are already fitted whit a moulded
plug incorporating a fuse, the value of which is 13A (indicated
on the pin face of the plug). Should the fuse need to be
replaced, an ASTA approved BS1362 fuse must be used of
the same ratingmarked
ASA
. This plug is not waterproof-
keep dry. Fuse cover are available from the "parts department"
indicated in your user instructions. If the plug supplied is not
suitable for your actual outlet, it should be cut off and
destroyed. If the fuse cover is detachable, never use the
plug with the cover omitted. If a replacement fuse cover is
required, ensure it is of the same colour asthat visible on the
pin face of the plug (ie red or orange). The end of the flexible
cable should be suitably prepared and the correct plug fitted.
* At 15°C and 1013 mbar-dry gas
Propane G31
H.s. = 50,37 MJ/kg
Table 1
Liquid gas
Natural gas
City gas
Burner
Diameter
(mm)
Thermal power
kW (H.s.*)
By-pass
1/100
(mm)
Nozzle
1/100
(mm)
Flow *
g/h
Nozzle
1/100
(mm)
Flow*
l/h
Nozzle
1/100
(mm)
Flow*
l/h
Nomin.
Reduc.
G30/31
G20
G110
Rapid C
100
3.00
0.7
40
86
218
116
286
260
680
Semi-rapid B
75
1.65
0.4
30
64
120
96
157
185
395
Auxiliary A
55
1.00
0.3
27
50
73
71
95
145
227
Triple ring D
130
3.25
1.3
57
91
236
124
309
285
770
Supply pressure
NOM.
MIN.
MAX
28-30
20
35
20
17
25
8
6
15
Butane G30
H.s. = 49,47 MJ/kg
Methane G20
H.s. = 37,78 MJ/m3
G110H.s. = 15,87 MJ/m3