Table 3: Summary of Volumes/Insulations
INSULATION
T =
30mm
30 < T <=
50 mm
50 < T <=
80 mm
80 < T
<= 100
mm
100 < T
<= 120
mm
120 < T
<= 150
mm
150 < T
<= 200
mm
-18°C FREEZER LITRES
V <= 20
SN
ST - T
20 < V <= 25
SN
ST - T
25 < V <= 40
SN - ST - T
40 < V <= 55
SN
ST -T
55 < V <= 65
SN
ST-T
65 < V <= 85
SN - ST
T
85 < V <= 130
SN
ST
T
130 < V <= 140
SN
ST
T
140 < V <= 200
SN
ST - T
T
The following tables contain the configurations of the compressor and evaporator
available for air-cooled models.
Table 4: Summary of configurations
Model
Compressor
Evaporator
Dimensions
Refrigerator
volume in L
Freezer
volume in L
GE80
BD35
Flat
350X250
80
26
GE150
BD35
Flat
386X361
150
50
2001
BD35
Oval
240X85X210
125
41
2301
BD35
Oval
320X100X230
150
50
2501
BD50
Oval
380X140X270
200
66
2005
BD35
Flat
350X130
60
20
2007
BD35
L
250+110X350
100
33
2010
BD35
L
400+170X210
125
41
2012
BD50
Flat
815X210
170
56
2016
BD50
Flat
1200X190
200
66
2017
BD50
Flat
1000X270
260
86
2013
BD50
Flat
1370X300
400
133
The refrigerator units are suitable for use with 12 Vdc or 24Vdc DC voltage systems. It
can be connected to 115VAC - 230VAC electrical mains using accessories, described
later in this manual.