to a standard control unit. In a continuous manner, a processor processes the
air temperature within the cooling compartment and modulates the number of
revolutions of the compressor by reducing them in proportion to the set/detected
temperature difference. Furthermore, when the system detects a surplus of
energy (motor on, electrical mains connected), the SEC processor works in order
to accumulate cooling energy in drinks and food, reducing the temperature inside
the compartment as much as possible without freezing them, re-using this energy
when the energy surplus is no longer. The SEC can be used in a fridge or freezer
system, bearing in mind that in the cooling power of the freezer configuration
must be at least 30% more than needed (therefore verify that the volume of the
compartment to be cooled is at least 30% lower than the maximum volume that
the unit is able to cool).
Note: Only compatible with Secop control unit mod. 101N0210 – 101N0212.
15 Evaporator bending zones based on models and measurements
Below are images of evaporator bending zones supplied by Indel Webasto Marine.
User Manual
89
Summary of Contents for Compact Classic
Page 5: ......